Description: Fusing central thermopile high temperature detection (software) Above (T3) degrees C detected for (t4) seconds continuously. Detection period 100ms, detection count: 10 times or more.
Remedy: • Replace the motor • Replace the HP sensor • Replace the fusing unit
Code: 549-02
Description: Shield Operation Error Detection During shield basic operation, shield sensor 2 does not go "Low > High" even if (t31) seconds elapsed from screen motor rotation start.
Remedy: • Replace the motor • Replace the HP sensor • Replace the fusing unit
Code: 549-03
Description: Shield Operation Error Detection During shield basic operation, shield motor does not stop even if (t32) seconds elapsed from rotation start.
Remedy: • Replace the motor • Replace the HP sensor • Replace the fusing unit
Code: SC101-01
Description: Lamp Error (Scanning) The white level peak did not reach the prescribed threshold when the white plate was scanned.
Causes: • LED defective • IDB (LED driver) defective • SBU defective • IPU defective • Power/signal harness defective • Condensation in scanner unit • Mirrors or lenses dirty or positioned incorrectly • White plate dirty or installed incorrectly
Remedy: 1. Turn the power off/on. 2. Perform the following operations: • Reconnect the power/signal harness. • Reattach/clean the mirrors/lenses. • Reattach/clean the white plate. 3. Replace the following parts: • Replace the LED board. • Replace the IDB board or SIO board. • Replace the SBU board. • Replace the IPU board. • Replace the power/signal harness.
Code: SC101-02
Description: Lamp Error (LED illumination adjustment) LED error was detected.
Remedy: 1. Turn the power off/on. 2. Perform the following operations: • Reconnect the power/signal harness. 3. Replace the following parts: • Replace the LED board. • Replace the IDB board or SIO board. • Replace the power/signal harness.
Code: SC102-00
Description: LED Illumination Adjustment Error The white level peak reached the prescribed threshold when the white plate was scanned after a specified number of adjustments.
Remedy: 1. Turn the power off/on. 2. Reconnect the power/signal harness. 3. Replace the following parts: • Replace the LED board. • Replace the SBU board. • Replace the IDB board or SIO board. • Replace the IPU board. • Replace the power/signal harness.