Các lỗi thường gặp

Code :
  • Code: SC361-03
  • Description: TD sensor output error: Upper Limit (M) TD sensor output: Vt (SP3-210-001 to 004) > output upper limit error threshold (SP3-211-002) continuously exceeded the upper limit occurrence threshold value (SP3-211-003).
  • Causes: TD sensor connector dropout (connection fault)
  • Remedy: 1. TD sensor connector missing check 2. Check whether there is any error in the TD sensor harness (disconnection, etc.) 3. If the sensor is defective, replace the development unit.
  • Code: SC361-04
  • Description: TD sensor output error: Upper Limit (Y) TD sensor output: Vt (SP3-210-001 to 004) > output upper limit error threshold (SP3-211-002) continuously exceeded the upper limit occurrence threshold value (SP3-211-003).
  • Causes: TD sensor connector dropout (connection fault)
  • Remedy: 1. TD sensor connector missing check 2. Check whether there is any error in the TD sensor harness (disconnection, etc.) 3. If the sensor is defective, replace the development unit.
  • Code: SC362-01
  • Description: TD sensor output error: Lower limit (K) TD sensor output: Vt (SP3-210-001 - 004) < output lower limit error threshold (SP3-211-004) is continuously below the lower limit occurrence threshold value (SP3-211-005)
  • Causes: TD sensor connector missing/dropout
  • Remedy: 1. TD sensor connector missing check 2. Check whether there is any error in the TD sensor harness (disconnection, etc.) 3. If the sensor is defective, replace the development unit.
  • Code: SC362-02
  • Description: TD sensor output error: Lower limit (C) TD sensor output: Vt (SP3-210-001 - 004) < output lower limit error threshold (SP3-211-004) is continuously below the lower limit occurrence threshold value (SP3-211-005)
  • Causes: TD sensor connector missing/dropout
  • Remedy: 1. TD sensor connector missing check 2. Check whether there is any error in the TD sensor harness (disconnection, etc.) 3. If the sensor is defective, replace the development unit.
  • Code: SC362-03
  • Description: TD sensor output error: Lower limit (M) TD sensor output: Vt (SP3-210-001 - 004) < output lower limit error threshold (SP3-211-004) is continuously below the lower limit occurrence threshold value (SP3-211-005)
  • Causes: TD sensor connector missing/dropout
  • Remedy: 1. TD sensor connector missing check 2. Check whether there is any error in the TD sensor harness (disconnection, etc.) 3. If the sensor is defective, replace the development unit.
  • Code: SC362-04
  • Description: TD sensor output error: Lower limit (Y) TD sensor output: Vt (SP3-210-001 - 004) < output lower limit error threshold (SP3-211-004) is continuously below the lower limit occurrence threshold value (SP3-211-005)
  • Causes: TD sensor connector missing/dropout
  • Remedy: 1. TD sensor connector missing check 2. Check whether there is any error in the TD sensor harness (disconnection, etc.) 3. If the sensor is defective, replace the development unit.
  • Code: SC370-01
  • Description: TM (ID) sensor calibration error (F) Regular reflection optical output voltage of the Front or Center or Rear TM (ID) sensor: Vsg_reg cannot be adjusted to within target range. Upper limit (SP3-320-013: initial value 4.5V) Lower limit (SP3-320-014: initial value 3.5V)
  • Causes: • TM (ID) sensor connector missing/ connection fault • TM (ID) sensor detection window dirt • TM (ID) sensor malfunction • Undulation in the ITB, or belt slippage
  • Remedy: • Remove image transfer unit, and check for TM (ID) sensor connector missing. If it is missing, reconnect it. • Check for dirt on the ID sensor detection window. If te detection window is dirty, clean by predetermined method (do not wipe dry). • Check the condition of the ITB. If undulation or belt slippage has occurred, re-install or replace the ITB. • If neither of the above have occurred, perform TM (ID) sensor replacement
  • Code: SC370-02
  • Description: TM (ID) sensor calibration error (C) Regular reflection optical output voltage of the Front or Center or Rear TM (ID) sensor: Vsg_reg cannot be adjusted to within target range. Upper limit (SP3-320-013: initial value 4.5V) Lower limit (SP3-320-014: initial value 3.5V)
  • Causes: • TM (ID) sensor connector missing/ connection fault • TM (ID) sensor detection window dirt • TM (ID) sensor malfunction • Undulation in the ITB, or belt slippage
  • Remedy: • Remove image transfer unit, and check for TM (ID) sensor connector missing. If it is missing, reconnect it. • Check for dirt on the ID sensor detection window. If te detection window is dirty, clean by predetermined method (do not wipe dry). • Check the condition of the ITB. If undulation or belt slippage has occurred, re-install or replace the ITB. • If neither of the above have occurred, perform TM (ID) sensor replacement