Các lỗi thường gặp

Code :
  • Code: SC531-01
  • Description: Development Intake Fan/Right Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
  • Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective
  • Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan
  • Code: SC531-02
  • Description: Development Intake Fan/Left Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
  • Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective
  • Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan
  • Code: SC531-03
  • Description: Drive Cooling Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
  • Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective
  • Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan
  • Code: SC533-01
  • Description: PSU Exhaust Heat Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
  • Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective
  • Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan
  • Code: SC533-03
  • Description: PSU Cooling Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
  • Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective
  • Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan
  • Code: SC533-04
  • Description: Controller Box Cooling Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
  • Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective
  • Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan
  • Code: SC534-01
  • Description: Main Exhaust Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
  • Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective
  • Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan
  • Code: SC534-02
  • Description: Toner Supply Cooling Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
  • Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective
  • Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan