Description: Development Intake Fan/Right Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan
Code: SC531-02
Description: Development Intake Fan/Left Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan
Code: SC531-03
Description: Drive Cooling Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan
Code: SC533-01
Description: PSU Exhaust Heat Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan
Code: SC533-03
Description: PSU Cooling Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan
Code: SC533-04
Description: Controller Box Cooling Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan
Code: SC534-01
Description: Main Exhaust Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.
Remedy: • Replace the motor • Reset the connector • Replace the harness • Replace the IOB • Replace the fan
Code: SC534-02
Description: Toner Supply Cooling Fan Lock In the motor ON state, the value of the lock sensor is checked every 100msec. If a lock signal is not obtained for 50 times consecutively.