Các lỗi thường gặp

Code :
  • Code: SC557-00
  • Description: Zero Cross Frequency Exceeded In the event of an error
  • Causes: Frequency instability of commercial power line/Noise
  • Remedy:
  • Code: SC559-00
  • Description: Fusing Jam Detected for 3 Times Consecutively Fusing jam (does not reach fusing exit sensor) is detected for 3 times consecutively. • Detection conditions Displays the SC559-00 at the time of integrating the counter each time fusing jam occurs, became fusing jam counter value = 3. The counter value is retained without fusing jam also reset by OFF/ON the power supply. • Control ON/OFF And enables ON / OFF is this SC, the default is set to OFF, then ON at the time of customer requirements. SP1-142-001 0: OFF (default), 1: ON (Set at the time of customer requirements) • Counter reset condition occurs fusing jam 1. Normal paper exit has been done during this continuous fusing jam, fusing jam counter is reset. 2. When "1" is changed to "0" SP1-142-001, to reset the (SP9-912-001) fusing jam counter. 3. When after displaying SC559, SC release is made, reset the (SP9912-001) fusing jam counter.
  • Causes: Fusing unit paper jam
  • Remedy: Remove the jam
  • Code: SC561-00
  • Description: Pressurized Central Thermistor Disconnection Below 0 degree C (or below 3F9) detected for (t12) seconds continuously. Detection period 100ms, detection count: 10 times or more.
  • Causes: • Thermistor disconnection • Connector disconnected
  • Remedy: • Replace the thermistor • Reset the connector • Replace the connector • Replace the fusing unit
  • Code: SC562-02
  • Description: Pressurized Central Thermistor Does Not Reload Does not reach (T21) degree C after heater 1ON for (t3) seconds.
  • Causes: • Thermistor dirt • Thermistor deformation, float • Outside input voltage guarantee • After excess temperature rise prevention unit operation
  • Remedy: • Replace the thermistor • Make sure that the input voltage is within acceptable limits • Replace the fusing unit
  • Code: SC563-00
  • Description: Pressurized Central Thermistor High Temperature Detection (software) Above (T3) degrees C detected for (t4) seconds continuously. Detection period: 100ms, detection count: 10 times or more.
  • Causes: • Triac short-circuit • IOB defective • BCU defective
  • Remedy: • Replace the IOB • Replace the BCU • Replace the fusing unit
  • Code: SC564-00
  • Description: Pressurized Central Thermistor High Temperature Detection (hardware) Above (T4) degrees C detected
  • Causes: • Triac short-circuit • IOB controller defective • BCU controller defective • Fusing control: out of control
  • Remedy: • Replace the IOB • Replace the BCU • Replace the fusing unit
  • Code: SC569-00
  • Description: Depressurizing Error Detection Retry operation fails 3 times consecutively.
  • Causes: • Motor defective • Sensor defective • Filler modification, defective
  • Remedy: • Replace the motor • Replace the sensor • Replace the fusing unit
  • Code: SC571-00
  • Description: Pressurized Edge Thermistor Disconnection Below 0 degree C (or above 3F9) detected for (t12) continuously. Detection period: 100 ms, detection counts: 10 times or more.
  • Causes: • Thermistor disconnection • Connector disconnected
  • Remedy: • Replace the thermistor • Reset the connector • Replace the connector • Replace the fusing unit