Các lỗi thường gặp

Code :
  • Code: SC637-01
  • Description: Tracking Information Notification Error (Tracking application error) Tracking information was lost.
  • Causes: • Tracking SDK application error • Internal notification error
  • Remedy: Turn the main power off/on.
  • Code: SC637-02
  • Description: Tracking Information Notification Error (Management server error) Tracking information was lost.
  • Causes: Communication with tracking management server failed. • Network error • tracking management server error • Tracking SDK application error
  • Remedy: Turn the main power off/on.
  • Code: SC650-01
  • Description: Remote Service Modem Communication Error (Dialup authentication failure) • An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on. • Displayed only when an error is detected while RC Gate is operating. • SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).
  • Causes: Dialup authentication failure
  • Remedy: Check the following SPs. • SP5-816-156 • SP5-816-157
  • Code: SC650-04
  • Description: Remote Service Modem Communication Error (dialup failing because of incorrect modem configuration) • An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on. • Displayed only when an error is detected while RC Gate is operating. • SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).
  • Causes: Dialup failing because of incorrect modem configuration
  • Remedy: Check if the setting of SP5-816-160 is correct. If it is correct, then there is a software bug.
  • Code: SC650-05
  • Description: Remote Service Modem Communication Error (insufficient current or connection fault) • An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on. • Displayed only when an error is detected while RC Gate is operating. • SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).
  • Causes: Insufficient current or connection fault
  • Remedy: The line is not supported and nothing can be done.
  • Code: SC650-13
  • Description: Remote Service Modem Communication Error (RC Gate Type Mwas installed but modem is not present (detected during operation)) • An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on. • Displayed only when an error is detected while RC Gate is operating. • SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).
  • Causes: RC Gate Type Mwas installed but modem is not present (detected during operation)
  • Remedy: • If a modem board is not installed, install it. • Check again if the modem driver configurations (SP5-816-160, SP5-816-165 to 171, SP5-816-165 to 171) are correct. • If the problem is not solved, replace the modem.
  • Code: SC650-14
  • Description: Remote Service Modem Communication Error (RC Gate Type N was installed but modem is present or wired/wireless LAN is not working correctly) • An error related to communication (dialup connection, modem board etc.) using the RC Gate was detected or an error that prevents RC Gate operation was detected at power on. • Displayed only when an error is detected while RC Gate is operating. • SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).
  • Causes: RC Gate Type N was installed but modem is present or wired/wireless LAN is not working correctly
  • Remedy: • If a modem board is attached, remove it. • Check if wired/wireless LAN works.
  • Code: SC651-01
  • Description: Illegal Remote Service Dial-up (Chat program parameter error) An unexpected error occurred when RC Gate Type M dialed up the NRS Center.
  • Causes: Software bug
  • Remedy: Logging only.
‹ First  < 36 37 38 39 40 41 42 >  Last ›