Các lỗi thường gặp

Code :
  • Code: SC725-40
  • Description: 2nd Fold Motor Error (D615) • Motor driver detected an error. (SC from the first time)
  • Causes: • Overcurrent to the motor. • Motor drive overheat
  • Remedy: • Replace the controller board. • Replace the motor. • Replace the harness.
  • Code: SC725-41
  • Description: Crease Motor Error (D615) • Motor driver detected an error. (SC from the first time)
  • Causes: • Overcurrent to the motor. • Motor drive overheat
  • Remedy: • Replace the controller board. • Replace the motor. • Replace the harness.
  • Code: SC725-71
  • Description: Horizontal Transport Motor Error (D615) • Motor driver detected an error. (SC from the first time)
  • Causes: • Overcurrent to the motor. • Motor drive overheat
  • Remedy: • Replace the controller board. • Replace the motor. • Replace the harness.
  • Code: SC725-72
  • Description: Horizontal exit motor error (D615) • Motor driver detected an error. (SC from the first time)
  • Causes: • Overcurrent to the motor. • Motor drive overheat
  • Remedy: • Replace the controller board. • Replace the motor. • Replace the harness.
  • Code: SC725-73
  • Description: Horizontal exit motor error (D615) • Motor driver detected an error. (SC from the first time)
  • Causes: • Overcurrent to the motor. • Motor drive overheat
  • Remedy: • Replace the controller board. • Replace the motor. • Replace the harness.
  • Code: SC725-74
  • Description: Entrance JG Motor Error (D615) • When moving to the home position, home position was not detected within specified number of pulses (p0 pulses). (The first time: jam display, the second time: SC) • When moving from the home position, home position was still detected after specified number of pulses (p1 pulses). (The first time: jam display, the second time: SC) • Motor driver detected an error. (SC from the first time)
  • Causes: • Overcurrent to the motor. • Motor drive overheat • Connector disconnected
  • Remedy: • Replace the controller board. • Replace the motor. • Replace the harness. • Re-connect the connector. • Replace the sensor.
  • Code: SC740-01
  • Description: Downstream device communication error (D712) • Communication with the downstream device has established, but the device is not responding to the command sent out, even after being sent three times. • The port level of the downstream device does not become H level (break cancel) within specified time.
  • Causes: • Interface cable (between inserter and downstream device) connector disconnected or broken • PCB (of inserter or downstream device) defective
  • Remedy: • Reconnect or replace the interface cable (between inserter and downstream device) connector disconnected or broken • Replace the PCB.
  • Code: SC740-10
  • Description: Bottom Plate Lift Motor Error (D711) • The lift motor rotates in the ascending direction but the upper limit sensor does not detect within specified time (t0sec). (The first time: jam display, the second time: SC) • The lift motor rotates in the descending direction but the lower limit sensor does not detect within specified time (t0sec). (The first time: jam display, the second time: SC)
  • Causes: • Motor defective • Connecter disconnected • Overload • Upper limit sensor defective • Lower limit sensor defective
  • Remedy: • Check the motor and upper limit sensor. • Check the lower limit sensor. • Replace the motor/upper limit sensor./lower limit sensor. • Replace the PCB.