Description: File Format Converter (MLB) error GW A request to get access to the MLB was not answered within the specified time.
Causes: • MLB defective, replace the MLB
Remedy:
Code: SC900
Description: Electrical total counter error GW The total counter contains something that is not a number.
Causes: • NVRAM incorrect type • NVRAM defective • NVRAM data scrambled • Unexpected error from external source
Remedy:
Code: SC901
Description: Mechanical counter error At the beginning of a count, the machine detected that the mechanical was not connected. Note: This function is provided only in EXP machines.
Description: SC910 B External controller error 1 GW SC911 External controller error 2 GW SC912 External controller error 3 GW SC913 External controller error 4 GW SC914 External controller error 5 GW An external application sent an error notice.
Causes: • VLB defective • I/F cable defective
Remedy:
Code: SC919
Description: External controller down GW The EAC received an interrupt signal from the FLUTE serial driver during print jobs in progress and the connection between the copier and external controller was broken. Note: The EAC is the External API Converter.
Causes: 1. Turn the machine off. 2. Check the I/F cable to determine if it became disconnected during operation. 3. Turn the machine on.
Remedy:
Code: SC920
Description: Printer error 1 GW An internal application error was detected and operation cannot continue.
Causes: • Software defective; turn the machine off/on, or change the controller firmware • Insufficient memory
Remedy:
Code: SC921
Description: Printer error 2 GW When the application started, the necessary font was not on the SD card.
Causes: • Font not on the SD card
Remedy:
Code: SC954
Description: Printer Image Setting Error The IPU did not issue the signal required to start image processing for the printing mode within 60 s after the paper stops for registration.