Code: SC594

Description: Cutter 2 home position error 1: Lower Tray Both left and right cutter HP switches were on: Immediately after the machine was turned on. -or- After the upper tray was opened and close.
Causes: • Right or left cutter home position switch defective.
Remedy:

Code: SC595

Description: Cutter 2 home position error 2: Lower Tray The left home position switch remained on 300 ms after the cutter motor switched on.
Causes: • Cutter motor 1 harness loose, broken, defective • Cutter motor overload due to physical obstruction • Cutter motor 1 defective
Remedy:

Code: SC596

Description: Cutter 2 home position error 3: Upper Tray The home position switch remained off for 1 sec. after cutter motor 1 switched on.
Causes: • Cutter motor 1 harness loose, broken, defective • Cutter motor 1 overload due to physical obstruction • Cutter motor 1 defective
Remedy:

Code: SC628

Description: Fan folder communication error 1 The main machine issued a timeout three failed attempts to communicate with the fan folder unit. Possible causes: • There was no answer from the fan folder within 100 ms in response to data sent from the main machine. • The fan folder unit was switched off while folding was in progress. • The main machine received an illegal command from the fan folder. • 60 sec. after the main machine fed the document to the fan folder, the fan folder failed to notify the main machine that the folded document has exited the fan folder.
Causes: • Fan folder not connected to main machine • Fan folder main control unit connector loose, broken, defective • Fan folder main control unit defective
Remedy:

Code: SC629

Description: Fan folder communication error 2: Cross Folder There was no answer from the fan folder within 100 ms in response to data sent from the main machine.
Causes: • Fan folder not connected to main machine • Fan folder main control unit connector loose, broken, defective • Fan folder main control unit defective
Remedy:

Code: SC632

Description: Key/card counter device error 1 GW After 1 data frame is sent to the device, an ACK signal is not received within 100 ms, and is not received after 3 retries.
Causes: • The serial line from the device to the copier is unstable, disconnected, or defective.
Remedy:

Code: SC633

Description: Key/card counter device error 2 GW During communication with the device, the BCU received a break (Low) signal.
Causes: • The serial line from the device to the copier is unstable, disconnected, or defective.
Remedy:

Code: SC635

Description: Key/card counter device error 4 GW After installation of the device, a message alerts user to a battery voltage abnormal error.
Causes: • Device control board defective • Device control board backup battery defective