Description: Finisher Tray 1 shift motor error (B830)
The shift roller HP sensor of the upper tray does not activate within the prescribed time after the shift tray starts to move toward or away from the home position. The 1st detection failure causes a jam error, and the 2nd failure causes this SC code.
Causes: • Shift tray HP sensor of the upper tray disconnected, defective • Shift tray motor of the upper tray is disconnected, defective • Shift tray motor of the upper tray overloaded due to obstruction
Description: Upper Transport Motor Error (Proof Tray): B830
No encoder pulse signal is detected for the upper transport motor within 600 ms. The 1st failure causes this SC code.
Causes: • Upper transport motor disconnected, defective • Finisher connection to upper transport motor loose, defective • Upper transport motor blocked by an obstruction • Upper transport motor defective • Finisher main board defective
Description: Upper Tray Junction Gate Motor: 3K Finisher B830
The upper tray junction gate HP sensor did not detect the gate at the home position within 200 ms after two attempts. -or- The HP sensor twice detected the gate at the home position for more than 200 ms after it was supposed to open.
Causes: • Junction gate did not arrive at the home position within the specified time • Junction gate did not leave the home position within the specified time
Description: Staple Junction Gate Motor Error: B830
The staple tray junction gate HP sensor did not detect the gate at the home position within 200 ms after two attempts. -or- The HP sensor twice detected the gate at the home position for more than 200 ms after it was supposed to open.
Causes: • Junction gate did not arrive at the home position within the specified time • Junction gate did not leave the home position within the specified time
Description: Pre-Stack Junction Gate Motor Error: 3K Finisher B830
The pre-stack junction gate HP sensor did not detect the gate at the home position for within 200 ms after two attempts. -or- The HP sensor twice detected the gate at the home position for more than 200 ms after it was supposed to open.
Causes: • Junction gate did not arrive at the home position within the specified time • Junction gate did not leave the home position within the specified time