Description: Developer Fill Error: M
The PCU failed to fill with developer from the developer bottle when SP3814-1 was executed.
Causes: • Developer bottle not set correctly • Developer in the bottle is clogged and not flowing Note: For detailed information about how to handle problems developer filling, see "Handling Problems with Developer Filling" under "PCU" in Section 3.
Description: Developer Fill Error: C
The PCU failed to fill with developer from the developer bottle when SP3814-1 was executed.
Causes: • Developer bottle not set correctly • Developer in the bottle is clogged and not flowing Note: For detailed information about how to handle problems developer filling, see "Handling Problems with Developer Filling" under "PCU" in Section 3.
Description: Developer Fill Error: Y
The PCU failed to fill with developer from the developer bottle when SP3814-1 was executed.
Causes: • Developer bottle not set correctly • Developer in the bottle is clogged and not flowing Note: For detailed information about how to handle problems developer filling, see "Handling Problems with Developer Filling" under "PCU" in Section 3.
Description: TD sensor (Vt high) error: K
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Description: TD sensor (Vt high) error: M
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Description: TD sensor (Vt high) error: C
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Description: TD sensor (Vt high) error: Y
The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds 0.5V for 10 counts.
Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Description: TD sensor (Vt low) error: K
The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.