Các lỗi thường gặp

Code :
  • Code: SC365
  • Description: TD sensor (Vt low) error: M
    The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
  • Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC366
  • Description: TD sensor (Vt low) error: C
    The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
  • Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC367
  • Description: TD sensor (Vt low) error: Y
    The Vt value of the black, magenta, cyan, or yellow TD sensor is below 0.5V for 10 counts.
  • Causes: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC372
  • Description: TD sensor adjustment error: K
    During TD sensor initialization with SP3801, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of 2.5+-0.2V
  • Causes: TD harness sensor disconnected, loose or defective Harness between TD sensor and drawer disconnected, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC373
  • Description: TD sensor adjustment error: M
    During TD sensor initialization with SP3801, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of 2.5+-0.2V
  • Causes: TD harness sensor disconnected, loose or defective Harness between TD sensor and drawer disconnected, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC374
  • Description: TD sensor adjustment error: C
    During TD sensor initialization with SP3801, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of 2.5+-0.2V
  • Causes: TD harness sensor disconnected, loose or defective Harness between TD sensor and drawer disconnected, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC375
  • Description: TD sensor adjustment error: Y
    During TD sensor initialization with SP3801, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of 2.5+-0.2V
  • Causes: TD harness sensor disconnected, loose or defective Harness between TD sensor and drawer disconnected, defective • TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective.
  • Code: SC396
  • Description: Drum motor error: K
    The motor is trying to rotate at power on or during normal operation but there is an excessive load on the drum shaft. The motor has no traction (due to a bent cleaning blade, for example).
  • Causes: • Drum motor harness loose, broken, defective • Drum motor defective • DTMB defective