Các lỗi thường gặp

Code :
  • Code: 372
  • Description: TD sensor adjustment error: K. During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value (default: 2.5V) ±0.1V
  • Causes: • TD sensor harness disconnected, loose or defective • TD sensor defective
  • Remedy: 1. Check the harness connection of the TD sensor. 2. Replace the TD sensor.
  • Code: 373
  • Description: TD sensor adjustment error: C. During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value (default: 2.5V) ±0.1V
  • Causes: • TD sensor harness disconnected, loose or defective • TD sensor defective
  • Remedy: 1. Check the harness connection of the TD sensor. 2. Replace the TD sensor.
  • Code: 374
  • Description: TD sensor adjustment error: M. During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value (default: 2.5V) ±0.1V
  • Causes: • TD sensor harness disconnected, loose or defective • TD sensor defective
  • Remedy: 1. Check the harness connection of the TD sensor. 2. Replace the TD sensor.
  • Code: 375
  • Description: TD sensor adjustment error: Y. During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value (default: 2.5V) ±0.1V
  • Causes: • TD sensor harness disconnected, loose or defective • TD sensor defective
  • Remedy: 1. Check the harness connection of the TD sensor. 2. Replace the TD sensor.
  • Code: 388
  • Description: Quenching error: K. The drum potential sensor for a color detects 2.0V (Vd: 400V) or more for 0.3 seconds after the charge corona wire has turned off.
  • Causes: • Disconnected or broken harness of the quenching lamp • Dirty surface of the quenching lamp glass
  • Remedy: 1. Check the harness or harness connection. 2. Clean the surface of the quenching lamp glass.
  • Code: 389
  • Description: Quenching error: C. The drum potential sensor for a color detects 2.0V (Vd: 400V) or more for 0.3 seconds after the charge corona wire has turned off.
  • Causes: • Disconnected or broken harness of the quenching lamp • Dirty surface of the quenching lamp glass
  • Remedy: 1. Check the harness or harness connection. 2. Clean the surface of the quenching lamp glass.
  • Code: 390
  • Description: Quenching error: M. The drum potential sensor for a color detects 2.0V (Vd: 400V) or more for 0.3 seconds after the charge corona wire has turned off.
  • Causes: • Disconnected or broken harness of the quenching lamp • Dirty surface of the quenching lamp glass
  • Remedy: 1. Check the harness or harness connection. 2. Clean the surface of the quenching lamp glass.
  • Code: 391
  • Description: Quenching error: Y. The drum potential sensor for a color detects 2.0V (Vd: 400V) or more for 0.3 seconds after the charge corona wire has turned off.
  • Causes: • Disconnected or broken harness of the quenching lamp • Dirty surface of the quenching lamp glass
  • Remedy: 1. Check the harness or harness connection. 2. Clean the surface of the quenching lamp glass.