Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio Pro C720S — Trang 12/85

Code: 352

Description: Toner bottle motor error: K. If the error flag occurs for a toner bottle motor 5 times, the machine issues this SC. This error flag is calculated as follows. • The error flag of the toner bottle motor is made when the machine detects a LOCK signal of the toner bottle motor for 0.9 seconds during the toner bottle motor rotating (1 second). • The error flag of the toner bottle motor is cleared when the machine detects a LOCK signal of the toner bottle motor less than 0.9 seconds during the toner bottle motor rotating (1 second).
Causes: • Solidified toner in the toner bottle • Toner supply tube bent • Incorrect setting of the toner bottle • Broken toner bottle
Remedy: 1. Shake the toner bottle five or six times. 2. Check if the toner supply tube to sub-hopper unit is bent. 3. Check and reinstall the toner bottle. 4. Replace the toner bottle.

Code: 353

Description: Toner bottle motor error: C. If the error flag occurs for a toner bottle motor 5 times, the machine issues this SC. This error flag is calculated as follows. • The error flag of the toner bottle motor is made when the machine detects a LOCK signal of the toner bottle motor for 0.9 seconds during the toner bottle motor rotating (1 second). • The error flag of the toner bottle motor is cleared when the machine detects a LOCK signal of the toner bottle motor less than 0.9 seconds during the toner bottle motor rotating (1 second).
Causes: • Solidified toner in the toner bottle • Toner supply tube bent • Incorrect setting of the toner bottle • Broken toner bottle
Remedy: 1. Shake the toner bottle five or six times. 2. Check if the toner supply tube to sub-hopper unit is bent. 3. Check and reinstall the toner bottle. 4. Replace the toner bottle.

Code: 354

Description: Toner bottle motor error: M. If the error flag occurs for a toner bottle motor 5 times, the machine issues this SC. This error flag is calculated as follows. • The error flag of the toner bottle motor is made when the machine detects a LOCK signal of the toner bottle motor for 0.9 seconds during the toner bottle motor rotating (1 second). • The error flag of the toner bottle motor is cleared when the machine detects a LOCK signal of the toner bottle motor less than 0.9 seconds during the toner bottle motor rotating (1 second).
Causes: • Solidified toner in the toner bottle • Toner supply tube bent • Incorrect setting of the toner bottle • Broken toner bottle
Remedy: 1. Shake the toner bottle five or six times. 2. Check if the toner supply tube to sub-hopper unit is bent. 3. Check and reinstall the toner bottle. 4. Replace the toner bottle.

Code: 355

Description: Toner bottle motor error: Y. If the error flag occurs for a toner bottle motor 5 times, the machine issues this SC. This error flag is calculated as follows. • The error flag of the toner bottle motor is made when the machine detects a LOCK signal of the toner bottle motor for 0.9 seconds during the toner bottle motor rotating (1 second). • The error flag of the toner bottle motor is cleared when the machine detects a LOCK signal of the toner bottle motor less than 0.9 seconds during the toner bottle motor rotating (1 second).
Causes: • Solidified toner in the toner bottle • Toner supply tube bent • Incorrect setting of the toner bottle • Broken toner bottle
Remedy: 1. Shake the toner bottle five or six times. 2. Check if the toner supply tube to sub-hopper unit is bent. 3. Check and reinstall the toner bottle. 4. Replace the toner bottle.

Code: 356

Description: Development roller error: K. The development roller sensor for a color does not detect the rotation of the development roller for 0.5 seconds after the development motor for each color has turned on.
Causes: • Defective development unit drive gears • Defective development roller sensor
Remedy: 1. Replace the development unit drive gears. 2. Replace the development roller sensor.

Code: 357

Description: Development roller error: C. The development roller sensor for a color does not detect the rotation of the development roller for 0.5 seconds after the development motor for each color has turned on.
Causes: • Defective development unit drive gears • Defective development roller sensor
Remedy: 1. Replace the development unit drive gears. 2. Replace the development roller sensor.

Code: 358

Description: Development roller error: M. The development roller sensor for a color does not detect the rotation of the development roller for 0.5 seconds after the development motor for each color has turned on.
Causes: • Defective development unit drive gears • Defective development roller sensor
Remedy: 1. Replace the development unit drive gears. 2. Replace the development roller sensor.

Code: 359

Description: Development roller error: Y. The development roller sensor for a color does not detect the rotation of the development roller for 0.5 seconds after the development motor for each color has turned on.
Causes: • Defective development unit drive gears • Defective development roller sensor
Remedy: 1. Replace the development unit drive gears. 2. Replace the development roller sensor.