Code :
  • Code: 352
  • Description: Toner bottle motor error: K. If the error flag occurs for a toner bottle motor 5 times, the machine issues this SC. This error flag is calculated as follows. • The error flag of the toner bottle motor is made when the machine detects a LOCK signal of the toner bottle motor for 0.9 seconds during the toner bottle motor rotating (1 second). • The error flag of the toner bottle motor is cleared when the machine detects a LOCK signal of the toner bottle motor less than 0.9 seconds during the toner bottle motor rotating (1 second).
  • Causes: • Solidified toner in the toner bottle • Toner supply tube bent • Incorrect setting of the toner bottle • Broken toner bottle
  • Remedy: 1. Shake the toner bottle five or six times. 2. Check if the toner supply tube to sub-hopper unit is bent. 3. Check and reinstall the toner bottle. 4. Replace the toner bottle.
  • Code: 353
  • Description: Toner bottle motor error: C. If the error flag occurs for a toner bottle motor 5 times, the machine issues this SC. This error flag is calculated as follows. • The error flag of the toner bottle motor is made when the machine detects a LOCK signal of the toner bottle motor for 0.9 seconds during the toner bottle motor rotating (1 second). • The error flag of the toner bottle motor is cleared when the machine detects a LOCK signal of the toner bottle motor less than 0.9 seconds during the toner bottle motor rotating (1 second).
  • Causes: • Solidified toner in the toner bottle • Toner supply tube bent • Incorrect setting of the toner bottle • Broken toner bottle
  • Remedy: 1. Shake the toner bottle five or six times. 2. Check if the toner supply tube to sub-hopper unit is bent. 3. Check and reinstall the toner bottle. 4. Replace the toner bottle.
  • Code: 354
  • Description: Toner bottle motor error: M. If the error flag occurs for a toner bottle motor 5 times, the machine issues this SC. This error flag is calculated as follows. • The error flag of the toner bottle motor is made when the machine detects a LOCK signal of the toner bottle motor for 0.9 seconds during the toner bottle motor rotating (1 second). • The error flag of the toner bottle motor is cleared when the machine detects a LOCK signal of the toner bottle motor less than 0.9 seconds during the toner bottle motor rotating (1 second).
  • Causes: • Solidified toner in the toner bottle • Toner supply tube bent • Incorrect setting of the toner bottle • Broken toner bottle
  • Remedy: 1. Shake the toner bottle five or six times. 2. Check if the toner supply tube to sub-hopper unit is bent. 3. Check and reinstall the toner bottle. 4. Replace the toner bottle.
  • Code: 355
  • Description: Toner bottle motor error: Y. If the error flag occurs for a toner bottle motor 5 times, the machine issues this SC. This error flag is calculated as follows. • The error flag of the toner bottle motor is made when the machine detects a LOCK signal of the toner bottle motor for 0.9 seconds during the toner bottle motor rotating (1 second). • The error flag of the toner bottle motor is cleared when the machine detects a LOCK signal of the toner bottle motor less than 0.9 seconds during the toner bottle motor rotating (1 second).
  • Causes: • Solidified toner in the toner bottle • Toner supply tube bent • Incorrect setting of the toner bottle • Broken toner bottle
  • Remedy: 1. Shake the toner bottle five or six times. 2. Check if the toner supply tube to sub-hopper unit is bent. 3. Check and reinstall the toner bottle. 4. Replace the toner bottle.
  • Code: 356
  • Description: Development roller error: K. The development roller sensor for a color does not detect the rotation of the development roller for 0.5 seconds after the development motor for each color has turned on.
  • Causes: • Defective development unit drive gears • Defective development roller sensor
  • Remedy: 1. Replace the development unit drive gears. 2. Replace the development roller sensor.
  • Code: 357
  • Description: Development roller error: C. The development roller sensor for a color does not detect the rotation of the development roller for 0.5 seconds after the development motor for each color has turned on.
  • Causes: • Defective development unit drive gears • Defective development roller sensor
  • Remedy: 1. Replace the development unit drive gears. 2. Replace the development roller sensor.
  • Code: 358
  • Description: Development roller error: M. The development roller sensor for a color does not detect the rotation of the development roller for 0.5 seconds after the development motor for each color has turned on.
  • Causes: • Defective development unit drive gears • Defective development roller sensor
  • Remedy: 1. Replace the development unit drive gears. 2. Replace the development roller sensor.
  • Code: 359
  • Description: Development roller error: Y. The development roller sensor for a color does not detect the rotation of the development roller for 0.5 seconds after the development motor for each color has turned on.
  • Causes: • Defective development unit drive gears • Defective development roller sensor
  • Remedy: 1. Replace the development unit drive gears. 2. Replace the development roller sensor.