Code: 601

Description: Communication Error between BCU and MCU (D016/D097 only) One or more of the following occurred: • The BCU cannot communicate with the MCU (LCT-MF) within 100 ms after power on after 3 tries. • A BREAK signal was detected after connection between the BCU and MCU. • After a communication error, three tries to communicate with the MCU failed.
Causes: • Poor connection between BCU and MCU • BCU defective • MCU defective
Remedy: 1. Check or replace the harness between the BCU and MCU. 2. Replace the BCU. 3. Replace the MCU in the LCT-MF.

Code: 610

Description: Mechanical counter error: K. This SC is only for NA models. The machine detects the mechanical counter error.
Causes: • Disconnected mechanical counter • Defective mechanical counter
Remedy: Check or replace the mechanical counter.

Code: 611

Description: Mechanical counter error: FC. This SC is only for NA models. The machine detects the mechanical counter error.
Causes: • Disconnected mechanical counter • Defective mechanical counter
Remedy:

Code: 620

Description: ADF Communication Error (D016/D097 only) No reponse from the ADF to the ACK signal issued by the IPU.
Causes: • Poor connection between the IPU and ADF • Electrical noise interfering with communication between electrical components • ADF cable or connector loose, broken, defective • ADF defective • IPU defective
Remedy: 1. Check or replace the cable between IPU and ADF. 2. Replace the ADF. 3. Replace the IPU.

Code: 621

Description: Finisher communication error. While the IOB 2 communicates with an optional unit, an SC code is displayed if the IOB 2 receives the break signal which is generated by the peripherals only just after the main switch is turned on.
Causes: • Ring Binder (D392) or Perfect Binder (D391) is installed in the D097 or M078 model. • Finisher I/F cable problems • PSU-G problems in the machine • IOB 2 problems • BCU problems
Remedy: 1. Remove the Ring Binder (D392) or Perfect Binder (D391) from the D097 or M078 model. 2. Check if the finisher I/F cables are correctly connected. 3. Replace the PSU-G if no power is supplied to peripherals. 4. Replace the IOB 2. 5. Replace the BCU.

Code: 623

Description: 2nd LCT communication error While the IOB 2 communicates with an optional unit, an SC code is displayed if the IOB 2 receives the break signal which is generated by the peripherals only just after the main switch is turned on.
Causes: • LCT I/F cable problems • LCT power supply harness problems • IOB 2 problems • BCU problems
Remedy: 1. Check if the LCT I/F cable is correctly connected. 2. Check if the harnesses of the LCT are correctly connected. 3. Replace the IOB 2. 4. Replace the BCU.

Code: 625

Description: RCB module version error The RCB module version in the main machine does not match the one in the LCT.
Causes: • Incorrect registration unit installed
Remedy: Install the correct registration unit.

Code: 626

Description: BCU-RCB communication error The BCU does not receive an OK signal from RCB for a certain time after sending a command to it and the BCU still does not receive an OK signal after sending the command 3 times.
Causes: • Registration drawer connection defective • RCB software not installed correctly • Defective BCU • Defective RCB
Remedy: 1. Check the connection between the above devices. 2. Replace the RCB. 3. Replace the BCU.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie