Code: 675-001

Description: Board Power Error-2 PSU-EA1 ch2: 24V power off error The machine detects 24 V power off from the PSU-EA1.
Causes: • Harness broken or disconnected • Interlock signal from IOB 2 detected • RB defective • PSU-EA1 defective
Remedy: 1. Check or replace the harness. 2. Replace the PSU-EA1. 3. Replace the RB.

Code: 675-002

Description: Board Power Error-2 IOB 1: 24V_2AINT power off error The machine detects 24 V power off from the IOB 1.
Causes: • PSU-EA1 defective • FU105 on the IOB 1 shorted or opened
Remedy: 1. Replace the IOB 1. 2. Check or replace the PSU-EA1.

Code: 675-003

Description: Board Power Error-2 IOB 1: 24V_2BINT power off error The machine detects 24 V power off from the IOB 1.
Causes: • PSU-EA1 defective • FU104 on the IOB 1 shorted or opened
Remedy: 1. Replace the IOB 1. 2. Check or replace the PSU-EA1.

Code: 675-004

Description: Board Power Error-2 RCB: 24V_2BINT power off error The machine detects 24 V power off from the RCB.
Causes: • PSU-EA1 defective • IOB 1 defective • Registration unit disconnected
Remedy: 1. Check the registration unit connection. 2. Replace the IOB 1. 3. Check or replace the PSU-EA1.

Code: 675-005

Description: Board Power Error-2 IOB 1: 24VINT power off error The machine detects 24 V power off from the IOB 1.
Causes: • PSU-EA1 defective
Remedy: Check or replace the PSU-EA1.

Code: 675-006

Description: Board Power Error-2 IOB 1: 24VINTA power off error The machine detects 24 V power off from the IOB 1.
Causes: • PSU-EA1 defective • IOB 1 defective • FU104 on the IOB 1 shorted or opened
Remedy: 1. Replace the IOB 1. 2. Check or replace the PSU-EA1.

Code: 675-007

Description: Board Power Error-2 RCB: 24VINTA1 power off error The machine detects 24 V power off from the RCB.
Causes: • Registration unit disconnected • PSU-EA1 defective • IOB 1 defective
Remedy: 1. Check the registration unit connection. 2. Replace the IOB 1. 3. Check or replace the PSU-EA1.

Code: 675-008

Description: Board Power Error-2 RCB: 24VINTA2 power off error The machine detects 24 V power off from the RCB.
Causes: • Registration unit disconnected • PSU-EA1 defective • IOB 1 defective
Remedy: 1. Check the registration unit connection. 2. Replace the IOB 1. 3. Check or replace the PSU-EA1.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie