Causes: Under the condition that the Toner Cartridge has not reached the end, an error that no toner is supplied has been detected over n times in succession. n: The value was specified at SP2-931-005. • Disconnected or broken Solenoid: Upper cover. (Failed to open the toner supply shutter) • Disconnection of Toner Supply Clutch • Defective PCDU. (Toner leak) • Toner clogging
Remedy: • Check the connector connection or check for a broken wire. • Replace the Solenoid: Upper Cover • Replace the PCDU • Replace the Toner Cartridge.
Code: SC364-00
Description: Toner End Sensor output count error
Causes: Under the condition that the toner cartridge has not reached the end, an error that no toner is supplied has been detected over n times in succession. (where n is to be configured using SP2-931-003) • Bad connector contact or connector disconnected/wire broken • Failed TE sensor
Remedy: • Turn the main power of the printer OFF and then ON • Check the connector connection or check for broken wire. • Replace the LED Head. • Replace the TE sensor (using the same troubleshooting procedure as for the LED).
Code: SC440-00
Description: High voltage output error: Transfer unit
Causes: This SC is issued if the BICU detects a short in the power pack 10 times consecutively. Open circuit (+) / Short circuit (-)
Remedy: • Turn the main power OFF and then ON. • Replace the controller board. • Check the connector connection.
Code: SC498-00
Description: Temperature/humidity Sensor error
Causes: • Temperature sensor output error: Out of range between 0.76 V and 2.90 V • Humidity sensor output error: 2.4 V or more • Unmounted sensor (Disconnected connector or broken wire) • Failed sensor
Remedy: • Turn the main power OFF and then ON. • Check that the connector is set. • Set the sensor. • Replace the sensor. • Replace the connector.
Code: SC508-00
Description: By-pass bottom plate operation error
Causes: The signal from the by-pass bottom plate position sensor has not changed (the signal has not changed from ON to OFF or vice versa) for 4 seconds or more after the start of reverse Paper Feed Unit rotation, If the error is detected three times in succession, the SC number is displayed on the operation panel. • By-pass bottom plate sensor connector disconnected or other error • By-pass bottom plate sensor feeler stuck or other error
Remedy: • Turn the main power OFF and then ON. • Check and replace the by-pass bottom plate sensor connector connection. • Replace the by-pass bottom plate sensor feeler. • Replace the Paper Feed Motor. • Replace the harness. • Replace the BICU.
Code: SC520-00
Description: Main motor error
Causes: When the main motor is driven, the lock (state of rotation) signal is checked every 100 milliseconds. If the machine detects the lock signal in the High status 20 times in succession, it reports this error. • The main motor incurs too much load from a defective unit. • The main motor is defective.
Remedy: Replace the defective unit or the motor
Code: SC530-00
Description: Fusing fan error
Causes: The fan motor lock (rotating state) signal is sampled at 100 ms intervals and the machine fails to receive the lock signal 50 times in succession. • Failed fan motor • Disconnected connector
Remedy: • Replace the fan motor. • Check the connector. • Replace the harness. • Replace the IOB.
Code: SC531-00
Description: Development Cooling fan error
Causes: The fan motor lock (rotating state) signal is sampled at 100 ms intervals and the machine fails to receive the lock signal 50 times in succession. • Failed fan motor • Disconnected connector
Remedy: • Replace the fan motor. • Check the connector. • Replace the harness. • Replace the IOB.