Description: LD error The IPU detected a problem at the LD unit.
Causes: Defective LD unit. Disconnect harness. Disconnect LD Driver.
Remedy: • Connect the harness properly. • Replace the LD unit.
Code: 312
Description: Charge roller current leak The PWM duty output exceeded 50% for longer than 200 ms, indicating a leak in the charge roller current.fective BCU.
Causes: Cartridge (charge roller) defective. High voltage supply board defective. Disconnect harness.
Remedy: • Turn the Power Switch Off and On. • Connect the harness properly. • Replace the AIO unit. • Replace the High voltage power supply board.
Code: 320
Description: Development Bias leak The PWM duty output exceeded 50% for longer than 200 ms, indicating a leak in the charge roller current.
Causes: Bias applying section leak. High voltage supply board defective. Disconnect harness. Development Bias CN loose
Remedy: • Connect the harnesses properly. • Replace the AIO. • Replace High voltage power supply board.
Code: 440
Description: Primary Transfer PP output leak The PWM duty output exceeded 50% for longer than 200 ms, indicating a leak in the charge roller current.
Causes: High voltage supply board defective. Disconnect harness. Development Bias CN loose
Remedy: • Connect the harnesses properly. • Replace the AIO. • Replace High voltage power supply board.
Code: 500
Description: Main motor lock The machine does not detect a main motor lock signal within 1 second after the main motor starts to rotate. -or- The machine does not detect a main motor lock signal for 250 ms continuously while the main motor is rotating.
Causes: Mechanical overload on the drive mechanism. Main motor defectivess.
Remedy: • Remove foreign materials on the drive mechanism. • Turn the Power Switch Off and On. • Connect the harnesses properly. • Replace the main motor.
Code: 530
Description: Exhaust fan motor error The CPU detects an exhaust fan lock signal for more than 2 seconds.
Causes: Mechanical overload on the Exhaust fan mechanism. Exhaust fan harness loose or broken
Remedy: • Remove foreign materials on the drive mechanism. • Turn the Power Switch Off and On. • Connect the harnesses properly. • Replace the Exhaust fan.
Code: 531
Description: Reverse Fan Motor error The CPU detects a Reverse fan lock signal for more than 2 seconds.и#0
Causes: Mechanical overload on the Reverse fan mechanism. Reverse fan harness loose or broken
Remedy: • Remove foreign materials from the reverse fan. • Turn the Power Switch Off and On. • Connect the harnesses properly. • Replace the reverse fan.
Code: 532
Description: PSU Fan Motor error The CPU detects a PSU fan lock signal for more than 2 seconds.
Causes: Mechanical overload on the PSU fan mechanism. PSU fan harness loose or broken
Remedy: • Remove foreign materials from the PSU fan. • Turn the Power Switch Off and On. • Connect the harnesses properly. • Replace the PSU fan.