Description: BICU serial communication error: Time out
Causes: The serial communication error occurs in the BICU. • Noise • Defective BICU
Remedy: Replace the BICU.
Code: 680-002
Description: BICU serial communication error: Retry error
Causes: The serial communication error occurs in the BICU. • Noise • Defective BICU
Remedy: Replace the BICU.
Code: 680-003
Description: BICU serial communication error: Download error
Causes: The serial communication error occurs in the BICU. • Noise • Defective BICU
Remedy: Replace the BICU.
Code: 680-004
Description: BICU serial communication error: UART error
Causes: The serial communication error occurs in the BICU. • Noise • Defective BICU
Remedy: Replace the BICU.
Code: 681
Description: RFID: Communication error Communication error occurs when the RFID board starts to communicate with the ID chip. Retry of RFID communication fails three times after the machine has detected the RFID communication error.
Causes: • Defective RFID board • Disconnected ASAP I/F • No memory chip on the AIO • Noise
Remedy:
Code: 683
Description: RFID: Unit check error The machine gets RFID communication error even the AIO has not been installed in the machine.
Causes: External noise
Remedy:
Code: 687
Description: Memory address (PER) command error The BICU did not receive a memory address command from the controller with the prescribed time once the paper reached the registration sensor.
Causes: • Harness connection at BICU, Controller board loose or broken • Defective BICU • Defective Controller Board
Remedy:
Code: 688
Description: Print request (PRREQ) command error The BICU did not receive a print request command from the controller with the prescribed time once the paper reached the registration sensor.
Causes: • Harness connection at BICU, Controller board loose or broken • Defective BICU • Defective Controller Board