Causes: The software attempted to perform an unexpected operation due to: 1) software bug, 2) incorrect internal parameter, 3) insufficient working memory.
Remedy: • Turn the machine power off/on • Reinstall the controller and/or main firmware Note: When this SC occurs, the file name, address, and data will be stored in NVRAM. This information can be checked by using SP7-403. Note the above data and the situation in which this SC occurs. Then report the data and conditions to your technical control center.
Causes: -001 • Defective BICU Input the serial number with SP5811-004, and turn the main power switch off/on. -002 • Defective NVRAM on the controller • Defective controller 1. Install a new NVRAM, and turn off and on the main power switch after SC995-002 has occurred. 2. Reinstall the previous NVRAM or download the information with SP5825-001, after that turn the main power off and on. -003 • Incorrect type controller installed • Defective controller Replace the controller board with the correct type. -004 • Incorrect model controller installed. Replace the controller with the correct model.
Causes: Application selected by the operator did not start or end normally due to a software problem. An option required by the application may not be installed.
Remedy: • Confirm which devices are required for the application. • Make sure all devices are configured correctly. • If the problem is with the fax unit, the nesting of the fax group may be too complicated
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.