Description: High voltage power board: Charge voltage output error [K] The measured voltage is not proper when EGB measures the charge output for each color.
Causes: Defective charge roller. Defective connectors. Disconnected harness. Defective high voltage power 1.
Remedy: 1. Check the connectors. 2. Replace the PCU for black. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.
Description: High voltage power board: Charge voltage output error [M] The measured voltage is not proper when EGB measures the charge output for each color.
Causes: Defective charge roller. Defective connectors. Disconnected harness. Defective high voltage power 1.
Remedy: 1. Check the connectors. 2. Replace the PCU for magenta. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.
Description: High voltage power board: Charge voltage output error [C] The measured voltage is not proper when EGB measures the charge output for each color.
Causes: Defective charge roller. Defective connectors. Disconnected harness. Defective high voltage power 1.
Remedy: 1. Check the connectors. 2. Replace the PCU for cyan. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.
Description: High voltage power board: Charge voltage output error [Y] The measured voltage is not proper when EGB measures the charge output for each color.
Causes: Defective charge roller Defective connectors Disconnected harness Defective high voltage power 1