Mã lỗi Ricoh Aficio SPC811DN — Trang 23/23

Code: 991

Description: Software continuity error
The software has attempted to perform an unexpected operation. However, unlike SC 990, the object of the error is continuity of the software.
Causes: • Software program error • Internal parameter incorrect, insufficient working memory.
Remedy: 1. This SC is not displayed on the LCD (logging only).

Code: 992

Description: Undefined error
Defective software program
Causes: • An error undetectable by any other SC code occurred
Remedy:

Code: 998

Description: Application start error
No applications start within 60 seconds after the power is turned on.
Causes: • Loose connection of RAM-DIMM, ROM-DIMM • Defective controller • Software problem
Remedy: 1. Check the setting of SP5875-001. If the setting is set to "1 (OFF)", change it to "0 (OFF)". 2. Check if the RAM-DIMM and ROM-DIMM are correctly connected. 3. Reinstall the controller system firmware. 4. Replace the controller.