Description: Pressure roller thermistor error 5: Lamp remains on
After hot roller reaches warmup temperature, the pressure roller fusing lamp remains for 6 sec. while the hot roller is not rotating.
Causes: • Thermistor damaged, or out of position • Fusing lamp disconnected, broken
Code: SC556
Description: Heating roller thermistor 2 error 5: Lamp remains on
After hot roller reaches warmup temperature, the pressure roller fusing lamp remains for 6 sec. while the hot roller is not rotating.
Causes: • Thermistor damaged, or out of position • Fusing lamp disconnected, broken
Code: SC561
Description: Hot roller thermistor error 1: Thermistor disconnected
The temperature measured by the hot roller thermistor does not reach the prescribed warm-up temperature within 100 sec.
Causes: • Loose connection of the hot roller thermistor • Defective hot roller thermistor • Defective BCU
Code: SC562
Description: Hot roller thermistor error 2: Failure to reach warmup temperature
After the main switch is turned on or the cover is closed, the heating roller temperature does not reach the ready temperature within 2 sec. after the heater switches on. -or- If the roller was below 45°C, the heating roller did not reach the ready temperature 2 sec. after reaching 45°C. Note: Thermistor 2 stops monitoring the temperature once Thermistor 1 detects ready temperature.
Causes: • Hot roller fusing lamp broken • Defective hot roller thermistor • Defective BCU
Code: SC563
Description: Hot roller thermistor error 3: Software - High Temperature
The thermistor detected a temperature over 250°C 10 times within 1 sec.
Causes: • TRIAC short • IOB defective • BICU defective • Fusing temperature control is erratic
Code: SC564
Description: Hot roller thermistor error 4: Hardware - High Temperature
The thermistor detected a temperature over 260°C.
Causes: • TRIAC short • IOB defective • BICU defective • Fusing temperature control is erratic
Code: SC565
Description: Hot roller thermistor error 5: Lamp remains on
After hot roller reaches warmup temperature, the hot roller fusing lamp remains for 6300 sec. while the hot roller is not rotating.
Causes: • Thermistor damaged, or out of position • Fusing lamp disconnected, broken
Code: SC620
Description: ARDF communication error
A BREAK signal occurs after the machine detects the ARDF, or a communication timeout occurs.
Causes: • ARDF disconnected • IPU board harness disconnected, defective • IPU board defective • Spurious noise from the power supply line • ARDF control board defective