Description: Potential sensor error 3: Vd Adjustment C
The development potential of the drum before exposure (Vd) cannot be adjusted to within ±10 V of the target voltage 900V).
Causes: • Toner density low
Code: SC423
Description: Potential sensor error 4: Vd Adjustment Y
The development potential of the drum before exposure (Vd) cannot be adjusted to within ±10 V of the target voltage 900V).
Causes: • Toner density low
Code: SC424
Description: Potential sensor error 5: Vl adjustment K
Vpl could not be adjusted to within ±10V of the target Vpl after exposure of the ID sensor patterns.
Causes: • Toner density low
Code: SC425
Description: Potential sensor error 6: Vl adjustment M
Vpl could not be adjusted to within ±10V of the target Vpl after exposure of the ID sensor patterns.
Causes: • Toner density low
Code: SC426
Description: Potential sensor error 7: Vl adjustment C
Vpl could not be adjusted to within ±10V of the target Vpl after exposure of the ID sensor patterns.
Causes: • Toner density low
Code: SC427
Description: Potential sensor error 8: Vl adjustment Y
Vpl could not be adjusted to within ±10V of the target Vpl after exposure of the ID sensor patterns.
Causes: • Toner density low
Code: SC432
Description: Potential sensor error 1: Vr K
Vr > 200V The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V.
Causes: • Toner density low
Code: SC433
Description: Potential sensor error 2: Vr M
Vr > 200V The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is greater than 200V.