Các lỗi thường gặp

Code :
  • Code: SC485
  • Description: Waste toner bottle motor error
    The lock signal of the waste toner bottle motor remains HIGH for more than 600 ms.
  • Causes: • Waste toner bottle motor defective
  • Code: SC487
  • Description: Waste toner bottle set error
    The set sensor of the waste toner bottle remains LOW for more than 500 ms. (The sensor goes HIGH when the bottle is installed correctly.)
  • Causes: • Install the waste toner bottle • Remove waste toner bottle and reinstall correctly
  • Code: SC488
  • Description: Waste toner transport lock
    Waste toner cannot be transported to the waste toner bottle.
  • Causes: • Blockage in the line to the waste toner bottle
  • Code: SC496
  • Description: MUSIC sensor error
    The MUSIC sensor detected an abnormal pattern on the ITB because: • ADC exceeded upper or lower limit. • The pattern used to calculate the amount of skew is abnormal. • The reading of the pattern exceeded the length of time the LED projected light. • LED light could not be adjusted correctly.
  • Causes: • MUSIC sensor defective or disconnected • MUSIC pattern abnormal; do a forced process control (SP3821) and check the result (section 4.2.4).
  • Code: SC497
  • Description: Temperature and humidity sensor error 1: PCU
    The thermistor output of the temperature and humidity sensor above the black PCU was not within the prescribed range (0.5V to 4.2V)
  • Causes: • Temperature and humidity sensor harness disconnected, loose, defective • Temperature and humidity sensor defective
  • Code: SC498
  • Description: Temperature and humidity sensor error 2
    The thermistor output of the temperature and humidity sensor at below the waste toner bottle was not within the prescribed range (0.5V to 4.2V)
  • Causes: • Temperature and humidity sensor harness disconnected, loose, defective • Temperature and humidity sensor defective
  • Code: SC503
  • Description: Tray 1 feed error
    • The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate. • When the tray lowers, the tray lift sensor does not go off within 1.5 sec.
  • Causes: • Tray lift motor defective or disconnected • Paper or other obstacle trapped between tray and motor • Pick-up solenoid disconnected or blocked by an obstacle
  • Code: SC504
  • Description: Tray 2 feed error
    • The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate. • When the tray lowers, the tray lift sensor does not go off within 1.5 sec.
  • Causes: • Tray lift motor defective or disconnected • Paper or other obstacle trapped between tray and motor • Pick-up solenoid disconnected or blocked by an obstacle