Description: Thermistor disconnection (heating roller)
The fusing unit starts warm up to the print ready temperature. The temperature does not reach 0°C for 10 seconds.
Description: Fusing warm-up timeout (heating roller)
The main switch is turned on or a cover is closed. The heating roller does not reach the warm-up temperature within 4 seconds.
Description: Full power error (heating roller)
Fusing unit warm-up is complete. The heating roller stops turning. The heating roller lamp keeps outputting the maximum power for 12 seconds.
Description: Unstable temperature (heating roller)
The heating roller thermistor detects unstable temperature increases or decreases within 60 seconds.
Description: Zero cross error
The main power is turned on and the machine checks how many zero-cross signals are generated during 500 ms. If the number of zero-cross signal generated is more than 66 or less than 45 and when this condition is detected 10 consecutive times, this code is displayed.
Causes: • Replace the PSU. • FU12 is open.
Code: 551
Description: Thermistor disconnection (pressure roller)
The pressure roller thermistor detects 7°C or lower for 80 seconds.