Description: Polygon motor error
• The polygon motor starts operating or changes its speed. The lock signal is not detected within 5 seconds. • The polygon motor stops operating. The lock signal is still detected for 3 seconds. • The polygon motor is operating. The lock signal remains undetected for 0.5 seconds.
Causes: • Defective polygon motor • Defective harness
Code: 220
Description: 1st beam synchronization error
A polygon motor lock is detected; the LD door is closed; and the LD remains on. The LD error (1st beam synchronization error) continues for 0.5 seconds.
Description: 2nd beam synchronization error
A polygon motor lock is detected; the LD door is closed; and the LD remains on. The LD error (2nd beam synchronization error) continues for 0.5 seconds.
Description: FGATE on error
A transfer belt mark is detected. No FGATE on signal is detected within 1 second.
Causes: • Defective BICU
Code: 231
Description: FGATE off error
An FGATE assert signal is detected. The FGATE negate signal is not detected within 30 seconds.
Causes: • Defective BICU
Code: 241
Description: LD error
An LD error continues for 0.5 seconds. (After an LD error is detected, an LD error release is written to the GAVD chip during monitoring.)
Causes: • Defective LD unit
Code: 280
Description: Image transfer belt mark detection error
• An imaging process starts. No belt mark for the first color is detected within 5 seconds. • A color imaging process starts. A belt mark other than the one for the first color is not detected within 8 seconds after a former belt mark has been detected.
Causes: • Defective BICU • Poor electrical connection between sensor and BICU
Code: 282
Description: GAVD communication error
Data is transferred. The status register in the BICU does not get to the ready condition within 10 milliseconds.