Description: AC charge output error 2: M
An interrupt checks the status of the power pack every 2 ms. This SC is issued if the BCU detects a short in the AC charge for black, magenta, cyan, or yellow (V = 0, for example) for 500 ms (250 times).
Causes: • High voltage power supply • BCU defective • OPC unit defective
Code: SC302
Description: AC charge output error 3: C
An interrupt checks the status of the power pack every 2 ms. This SC is issued if the BCU detects a short in the AC charge for black, magenta, cyan, or yellow (V = 0, for example) for 500 ms (250 times).
Causes: • High voltage power supply • BCU defective • OPC unit defective
Code: SC303
Description: AC charge output error 4: Y
An interrupt checks the status of the power pack every 2 ms. This SC is issued if the BCU detects a short in the AC charge for black, magenta, cyan, or yellow (V = 0, for example) for 500 ms (250 times).
Causes: • High voltage power supply • BCU defective • OPC unit defective
Code: SC312
Description: Charge, development error 1: K
500 ms after the black, magenta, cyan, and yellow drums start to rotate, the machine starts to monitor the AC current feedback at 8 ms intervals. This is SC is issued if the feedback for the charge unit of any color drops below 0.5V for 400 ms (50 consecutive readings).
Causes: • Make sure that the settings of SP2202 are at the defaults. • Defective charge roller • Defective power pack
Code: SC313
Description: Charge, development error 2: M
500 ms after the black, magenta, cyan, and yellow drums start to rotate, the machine starts to monitor the AC current feedback at 8 ms intervals. This is SC is issued if the feedback for the charge unit of any color drops below 0.5V for 400 ms (50 consecutive readings).
Causes: • Make sure that the settings of SP2202 are at the defaults. • Defective charge roller • Defective power pack
Code: SC314
Description: Charge, development error 3: C
500 ms after the black, magenta, cyan, and yellow drums start to rotate, the machine starts to monitor the AC current feedback at 8 ms intervals. This is SC is issued if the feedback for the charge unit of any color drops below 0.5V for 400 ms (50 consecutive readings).
Causes: • Make sure that the settings of SP2202 are at the defaults. • Defective charge roller • Defective power pack
Code: SC315
Description: Charge, development error 4: Y
500 ms after the black, magenta, cyan, and yellow drums start to rotate, the machine starts to monitor the AC current feedback at 8 ms intervals. This is SC is issued if the feedback for the charge unit of any color drops below 0.5V for 400 ms (50 consecutive readings).
Causes: • Make sure that the settings of SP2202 are at the defaults. • Defective charge roller • Defective power pack
Code: SC316
Description: AC bias charge adjustment error 1: K
An average value of 8 ms/cycle could not be attained for Vpp (AC charge bias) within 15 attempts. -or- The output of the AC charge boosted Vpp over 2.8 kV.
Causes: • Charge roller dirty • Charge roller defective • Bias terminal connection at the PCU receptacle is dirty or defective