Description: AC bias charge adjustment error 2: M
An average value of 8 ms/cycle could not be attained for Vpp (AC charge bias) within 15 attempts. -or- The output of the AC charge boosted Vpp over 2.8 kV.
Causes: • Charge roller dirty • Charge roller defective • Bias terminal connection at the PCU receptacle is dirty or defective
Code: SC318
Description: AC bias charge adjustment error 3: C
An average value of 8 ms/cycle could not be attained for Vpp (AC charge bias) within 15 attempts. -or- The output of the AC charge boosted Vpp over 2.8 kV.
Causes: • Charge roller dirty • Charge roller defective • Bias terminal connection at the PCU receptacle is dirty or defective
Code: SC319
Description: AC bias charge adjustment error 4: Y
An average value of 8 ms/cycle could not be attained for Vpp (AC charge bias) within 15 attempts. -or- The output of the AC charge boosted Vpp over 2.8 kV.
Causes: • Charge roller dirty • Charge roller defective • Bias terminal connection at the PCU receptacle is dirty or defective
Code: SC320
Description: Development power pack error 1: K
An interrupt checks the status of the each power pack every 2 ms. This SC is issued if the BCU detects a short in the development DC charge for black, magenta, cyan, or yellow (or V = 0) for 500 ms (250 times).
Causes: • Development power pack defective • High voltage power supply defective • High voltage power supply harness defective • Development unit defective • IOB harness disconnected or defective • IOB defective
Code: SC321
Description: Development power pack error 2: M
An interrupt checks the status of the each power pack every 2 ms. This SC is issued if the BCU detects a short in the development DC charge for black, magenta, cyan, or yellow (or V = 0) for 500 ms (250 times).
Causes: • Development power pack defective • High voltage power supply defective • High voltage power supply harness defective • Development unit defective • IOB harness disconnected or defective • IOB defective
Code: SC322
Description: Development power pack error 3: C
An interrupt checks the status of the each power pack every 2 ms. This SC is issued if the BCU detects a short in the development DC charge for black, magenta, cyan, or yellow (or V = 0) for 500 ms (250 times).
Causes: • Development power pack defective • High voltage power supply defective • High voltage power supply harness defective • Development unit defective • IOB harness disconnected or defective • IOB defective
Code: SC323
Description: Development power pack error 4: Y
An interrupt checks the status of the each power pack every 2 ms. This SC is issued if the BCU detects a short in the development DC charge for black, magenta, cyan, or yellow (or V = 0) for 500 ms (250 times).
Causes: • Development power pack defective • High voltage power supply defective • High voltage power supply harness defective • Development unit defective • IOB harness disconnected or defective • IOB defective
Code: SC324
Description: Development motor error 1: K
The PLL lock signal remained HIGH or LOW for longer than the prescribed time for the development motor of the affected color.
Causes: • Development motor shaft locked, blocked by and obstruction • DRB (Drive Board) defective