Các lỗi thường gặp

Code :
  • Code: 543
  • Description: Fusing overheat error 1
    A fusing temperature over 230°C is detected for 5 second by the fusing thermistor.
  • Causes: • TRIAC short on PSU (PSU defective) • SBCU board defective • Fusing thermistor defective
  • Code: 544
  • Description: Fusing overheat error 2
    • A fusing temperature over 250°C is detected by the fusing temperature monitor circuit in the SBCU board. • The power was interrupted for more than 0.3 sec.
  • Causes: • TRIAC short on PSU (PSU defective) • SBCU board defective • Fusing thermistor defective • Voltage of power supply unstable
  • Code: 545
  • Description: Fusing overheat error 3
    After warmup, the hot roller attained full operating temperature and maintained this temperature for 10 sec. without the hot roller rotating.
  • Causes: • Hot roller thermistor is out of its position because of incorrect installation
  • Code: 546
  • Description: Unstable fusing temperature
    The fusing temperature varies 50°C or more twice in succession within 1 sec.
  • Causes: • Thermistor disconnected or defective • Fusing unit drawer installed incorrectly
  • Code: 547
  • Description: Zero cross signal detection error
    Zero cross signals are not detected within a certain period.
  • Causes: • PSU defective • SBCU board defective
  • Code: 548
  • Description: Fusing unit set error
    The machine does not detect the fusing unit.
  • Causes: • Poor connection of the fusing unit • The fusing unit is not installed
  • Code: 557
  • Description: Zero cross waveform signal error
    The waveform of the zero cross signal was detected out of range.
  • Causes: • Electrical noise on the power supply line
  • Code: 590
  • Description: Exhaust fan motor error
    The CPU detects an exhaust fan lock signal for more than 3.5 seconds.
  • Causes: • Poor connection of the exhaust fan motor • Too much load on the motor drive