Description: Charge Corona Error 1: Charge Leak
A abnormal detection signal (H) was detected for more than 60 ms. Also, during this time, the detected voltage remained below –4V for more than 50 ms.)
Causes: • Cycle the machine off/on
• CGB power pack harness connectors loose, broken, defective
• Corona wire caps loose, missing
• CGB power pack defective
• Charge corona unit connectors loose, broken, defective
Description: Charge Corona Error 2: Grid Leak
A high feedback voltage (H) for the charge corona 60 ms. Also, during this time, the voltage of the charge grid remained less than –400V
Causes: • Cycle the machine off/on
• Charge unit set incorrectly (not locked in place)
• Charge unit connector loose, broken, defective
Description: Charge Corona Wire Cleaner Error 1
One of these occurred after the charge corona cleaner motor was switched on: • The charge corona wire cleaner motor remained locked within 10 sec after the motor switched on. • The charge corona wire cleaner motor failed to lock within 45 s after the start of cleaning.
Causes: • Cycle the machine off/on
• Charge corona wire cleaner motor defective
Description: Charge Corona Wire Cleaner Error 2
The cleaning pad of the charge corona wire cleaner mechanism failed to return to its home position.
Causes: Connectors between motor and IOB loose, broken, defective
• Charge wire dirty, defective, broken
• Wire cleaning pad defective
• Motor or motor board in motor unit defective
Description: Pre-Charge Output Error 1: Leak
An abnormal signal (H) was detected continuously for 60 ms. During this time the pre-charge unit voltage remained less than –3 kV for more than 50 ms.
Causes: • Pre-charge unit set incorrectly.
• Pre-charge unit contact is broken or defective.
Description: Pre-Charge Output Error 1: Grid Output
An abnormal signal (H) was detected continuously for 60 ms. During this time the pre-charge grid voltage remained less than –400V for more than 50 ms.
Causes: • Pre-charge unit set incorrectly
• Pre-charge unit contact is broken or defective
Description: Development Bias Error
An abnormal detection signal (H) was detected continuously for 60 ms. During this time the voltage exceeded –90µA for more than 50 ms
Causes: • Development power pack connectors loose, broken, defective
• Development unit connectors loose, broken, defective
• Development power pack defective
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.