Description: Communication Error Between BCU and ADF 1
There was no response from the ADF 100 ms after the ACK signal was sent to the ADF. Three attempts to resend the data failed.
Causes: • Poor connection between the BCU board and the ADF main board
• Interference from external noise on the harness between the BCU and ADF
Description: Communication Error Between BCU and Finisher
The BCU cannot communicate with the finisher properly. here was no response from the ADF 100 ms after the ACK signal was sent to the ADF. Three attempts to resend the data failed.
Causes: • Poor connection between the BCU board and the finisher main board
Description: Communication Error Between BCU and Finisher
A break signal (LOW) was detected.
Causes: • Poor connection between the BCU board and the finisher main board
• Finisher main board defective
• BCU board defective