Description: Fusing temperature warm-up error (center)
The fusing temperature rises less than 7 degrees in 2 seconds, and this continues 5 times consecutively. The fusing temperature is not detected in 25 or 35 seconds.
Causes: - Fusing thermistor defective or out of position
- Fusing lamp open
- Power supply board defective
Description: Fusing lamp overheat error (center)
After the fusing temperature reaches the target temperature, the fusing lamp does not turn off for 12 consecutive seconds.
Causes: - Fusing thermistor defective or out of position
- Power supply board defective
Description: Zero cross signal malfunction
Zero cross signals are not detected within 5 seconds after the main power switch is turned on, or are not detected within 1 second after operation begins.
Causes: - Power supply board defective
- BICU defective
Description: Fusing thermistor open (rear)
The fusing temperature detected by the thermistor is below 71C and is not corrected after the main power switch is turned on.
Causes: - Fusing thermistor defective or out of position
- Power supply board defective
- Loose connectors
Description: Fusing temperature warm-up error (rear)
The fusing temperature rises less than 7 degrees in 2 seconds, and this continues 5 times consecutively. The fusing temperature is not detected in 25 or 35 seconds.
Causes: - Fusing thermistor defective or out of position
- Fusing lamp open
- Power supply board defective
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.