Description: TD sensor initial setting error
TD sensor initial setting is not performed correctly.
Causes: • ID sensor defective • No developer • Drum does not turn • Development roller does not turn • Poor connection of the PCU • The voltage is not applied to charge roller
Description: Transfer roller leak error 2
A current leak signal for the transfer roller is detected. A current feedback signal for the transfer roller is not detected.
Causes: • High voltage supply board defective • Poor connection of the PCU • Transfer/separation unit set incorrectly • Transfer roller damaged
Description: Toner supply motor: Excess current error
The machine detects the current of 1A or more supplied to the toner supply motor for 0.2 seconds.
Description: Main motor lock
A main motor lock signal is not detected for more than 7 consecutive checks (700 ms) after the main motor starts to rotate, or the lock signal is not detected for more than 7 consecutive checks during rotation after the last signal.
Causes: • Too much load on the drive mechanism • Main motor defective
Description: Tray 1 lift motor malfunction
The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for 18 seconds.
Causes: • Paper lift sensor defective • Tray lift motor defective • Too much load on the drive mechanism • Poor tray lift motor connection
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.