Description: Counter device error 1 After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms.
Causes: • Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged • Make sure that SP5113 is set to enable the optional counter device.
Description: Counter device error 2 After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms.
Causes: • Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged • Make sure that SP5113 is set to enable the optional counter device.
Causes: 01 D Expanded authentication module error There is no expanded authentication module in the machine. The SD card or the file of the expanded authentication module is broken. There is no DESS module in the machine. • No expanded authentication module • Defective SD card • No DESS module 1. Install the expanded authentication module. 2. Install the SD card. 3. Install the DESS module. 02 D Version error The version of the expanded authentication module is not correct. • Incorrect module version 1. Install the correct file of the expanded authentication module.
Description: Communication error of the remote service modem (Cumin-M)
Causes: -001 - Authentication error The authentication for the RCG-M fails at a dial up connection. • Incorrect SP settings • Disconnected telephone line • Disconnected modem board Disconnected Local Area Network card Check and set the correct user name (SP5816-156) and password (SP5816-157). -004 - Incorrect modem setting Dial up fails due to the incorrect modem setting. Same as -001 Check and set the correct AT command (SP5819-160). -005 - Communication line error The supplied voltage is not sufficient due to the defective communication line or defective connection. Same as -001 Consult with the user's local telephone company.
Description: Incorrect dial up connection -001: Program parameter error -002: Program execution error An unexpected error occurs when the modem (RCG-M) tries to call the center with a dial up connection.
Causes: • Caused by a software bug
Remedy: No action required because this SC does not interfere with operation of the machine.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.