Code: 562-03

Description: Heating roller warm-up error (sensor 3)
The center temperature of the heating roller does not reach the target reload permit pressure within the prescribed time.
Causes: Dirty thermopile lenses. Defective heating roller thermistor. Input voltage out of the warranty (out of specification).
Remedy: 1. Check and clean the thermopile lenses. 2. Replace the thermopile 3. Replace the thermistor.

Code: 563

Description: Pressure roller overheat (software error): Center
The temperature detected by the pressure roller thermistor stays at the prescribed temperature within the prescribed time.
Causes: Defective PSU. Defective BICU
Remedy: 1. Replace the PSU. 2. Replace the BICU.

Code: 564

Description: Pressure roller overheat (hardware error): Center
The temperature detected by the pressure roller thermistor detects prescribed temperature.
Causes: Defective BICU. Defective fusing control system.
Remedy: 1. Replace the thermistor. 2. Replace the BICU.

Code: 571

Description: Pressure roller thermistor error: End
The temperature detected by the pressure roller thermistor does not reach 0 °C within the prescribed time.
Causes: Loose connection of the pressure roller thermistor. Defective thermopile. Defective pressure roller thermistor.
Remedy: 1. Check if the pressure roller thermistor is firmly connected. 2. Replace the thermopile. 3. Replace the pressure roller thermistor.

Code: 572-03

Description: Heating roller warm-up error (sensor 4)
The temperature of the heating roller does not reach 20 °C within the prescribed time.
Causes: Dirty thermopile lenses. Defective heating roller thermistor. Input voltage out of the warranty (out of specification).
Remedy: 1. Check and clean the thermopile lenses. 2. Replace the thermopile 3. Replace the thermistor.

Code: 573

Description: Pressure roller overheat (software error): End
The temperature detected by the pressure roller thermistor stays at the prescribed temperature within the prescribed time.
Causes: Defective PSU. Defective BICU
Remedy: 1. Replace the PSU. 2. Replace the BICU.

Code: 574

Description: Pressure roller overheat (hardware error): End
The temperature detected by the pressure roller thermistor detects prescribed temperature.
Causes: Defective BICU. Defective fusing control system
Remedy: 1. Replace the thermistor. 2. Replace the BICU.

Code: 610

Description: Mechanical counter error: Bk
This SC is only for NA models. The machine detects the mechanical counter error when SP5987-001 is set to "1".
Causes: Disconnected mechanical counter. Defective mechanical counter.
Remedy: 1. Check or replace the mechanical counter.