Code: 543

Description: Fusing overheat error 1 (software detection)
A fusing temperature (at the center) of over 230 °C (446 °F) is detected for 1 second by the fusing thermistors at the center or at either end of the fusing roller.
Causes: • Power supply unit defective • I/O board (IOB) defective • BICU defective • TRIAC short on PSU (PSU defective)

Code: 544

Description: Fusing overheat error 1 (hardware detection)
A fusing temperature (at the center) over 250 °C is detected by the fusing temperature monitor circuit in the BICU board.
Causes: • I/O board (IOB) defective • BICU defective

Code: 545

Description: Fusing lamp consecutive full power 1
After warm-up the fusing lamp remains at full power for 15 seconds without the hot roller rotating.
Causes: • Disconnected or defective thermistors (center) • Defective fusing lamp

Code: 547

Description: Zero cross error
• The zero cross signal is detected three times even though the heater relay is off when turning on the main power. • The zero cross signal is not detected for 2 seconds even though the heater relay is on after turning on the main power or closing the front door. • The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected zero cross signal is less than 45.
Causes: • Defective fusing lamp relay • Defective fusing lamp relay circuit • Unstable power supply

Code: 551

Description: Fusing thermistor open (end)
The thermistor (end) detects 0°C or less for 5 sec.
Causes: • Fusing thermistor (end) disconnected • Fusing thermistor (end) connector defective

Code: 552

Description: Fusing temperature warm-up error (end)
This SC is generated if the following condition occurs:
• The thermistor (end) does not detect an 8°C increment in the fusing temperature for 7.5 sec. just after the fusing temperature reached 45 °C.
• The temperature of the end thermistor does not reach the target temperature for 31 seconds after the fusing lamps turned on.
Causes: • Thermistor warped or broken

Code: 553

Description: Fusing overheat error 1 (software detection)
A fusing temperature (at the end) of over 230 °C (446 °F) is detected for 1 second by the fusing thermistors at the center or at either end of the fusing roller.
Causes: • Power supply unit defective • I/O board (IOB) defective • BICU defective • TRIAC short on PSU (PSU defective)

Code: 554

Description: Fusing overheat error 1 (hardware detection)
A fusing temperature (at the end) over 250 °C is detected by the fusing temperature monitor circuit in the BICU board.
Causes: • I/O board (IOB) defective • BICU defective