Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh D129-17 MP4002 — Trang 10/24

Code: 636-11

Description: IC Card Error: OSM User Code File Error
The correct "usercode" file could not be found in the root folder of the SD card because the file is not present, or the existing file is corrupted or the wrong type file. Make sure the eccm.mod file is in the root folder of the SD card. Note: Check the eccm.mod file is in the root folder of the SD card.
Causes:

Code: 636-99

Description: IC Card Error: Management area error
The management number of the external authentication module exceeds the maximum limit.
Causes: • Software error

Code: 637-01

Description: Tracking Information Notice Error: Tracking Application Error
When the tracking information is lost, this SC is issued
Causes: The machine failed to give notice the tracking information to the tracking SDK application.
Tracking information is lost, and the machine cannot count correctly

Code: 637-02

Description: Tracking Information Notice Error: Tracking Information Notice Error
When the tracking information is lost, this SC is issued.
Causes: The machine failed to give notice the tracking information to the management server.
Tracking information is lost, and the machine cannot count correctly.

Code: 641

Description: BICU communication error
The BICU does not respond to the frame transmitted from the controller.
Causes: • Defective controller • Detective BICU

Code: 650-001

Description: Communication error of the remote service modem (Embedded RCG-M): Authentication error
The authentication for the Embedded RCG-M fails at a dial up connection.
Causes: • Incorrect SP settings • Disconnected telephone line • Disconnected modem board Check and set the correct user name (SP5816-156) and password (SP5816-157).

Code: 650-004

Description: Communication error of the remote service modem (Embedded RCG-M): Incorrect modem setting
Dial up fails due to the incorrect modem setting.
Causes: • Same as -001 Check and set the correct AT command (SP5816-160).

Code: 650-005

Description: Communication error of the remote service modem (Embedded RCG-M): Communication line error
The supplied voltage is not sufficient due to a defective communication line or defective connection.
Causes: • Same as -001 Consult with the user's local telephone company.