Code: 651-01

Description: Illegal Remote Service Dial-up An expected error occurred when Cumin-M dialed up the NRS Center.
Causes: • Software bug • No action is required because only the count is logged

Code: 652

Description: Remote service ID2 mismatching There was an authentication mismatch between ID2 for @Remote, the controller board, and NVRAM.
Causes: • Used controller board installed • Used NVRAM installed • An unexpected error occurs when the modem (Embedded RCG-M) tries to call the center with a dial up connection.

Code: 653

Description: Incorrect remote service ID2 ID2 stored in the NVRAM is incorrect.
Causes: • Used NVRAM installed • An unexpected error occured when the modem (Embedded RCG-M) tries to call the center with a dial up connection

Code: 670

Description: Engine start up error The BCU failed to respond within the prescribed time when the machine was turned on.
Causes: • Connections between BCU and controller board are loose, disconnected, or damaged

Code: 671

Description: Illegal Engine Board An illegal engine board was detected by the firmware at power on.
Causes: • Replace BICU

Code: 672

Description: Controller start up error • After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup. • After startup reset of the operation panel, the attention code (FDH) or the attention acknowledge code (FEH) was not sent from the controller within 30 sec.. • After the controller issued a command to check the ommunication line with the controller at 30-second intervals, the controller failed to respond twice.
Causes: • Controller stalled • Controller board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • The controller did not completely shut down when the switch was turned off.

Code: 700-01

Description: ARDF bottom plate lift motor • The bottom plate HP sensor does not detect the home position of the bottom plate after the bottom plate lift motor switches on and lowers the bottom plate. • The bottom plate position sensor does not detect the position of the plate after the lift motor switches on and raises the bottom plate.
Causes: • ARDF feed motor disconnected, defective • Bottom plate HP sensor disconnected, defective • ARDF main board defective

Code: 700-02

Description: ADF bottom plate motor error • Bottom plate position sensor does not detect the plate after the bottom plate lift motor switches on to lift the plate. • Bottom plate HP sensor does not detect the plate after the bottom plate motor reverses to lower the plate
Causes: • Bottom plate position sensor defective • Bottom plate HP sensor defective • Bottom plate motor defective • ADF main board defective