Description: Laser Synchronization Detector Error: K Leading Edge (Not LD0) While the polygon motor is rotating normally, no synchronizing detection signal is output for black, leading edge for any LD other than LD0.
Causes: • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
Description: FGATE ON error: K The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [K].
Causes: • Defective ASIC • Poor connection between controller and BICU. • Defective BICU
Description: FGATE OFF error: K • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [K]. • The PFGATE ON signal still asserts when the next job starts.
Description: Charge corona wire cleaner error 1 The charge cleaner pad does not arrive at the home position: Motor locked within 4 s after switching on, or does not lock within 30 s. Motor locked within 10 s after reversing, or does not lock within 30 s.
Causes: • Charge corona wire cleaner motor defective • Motor driver defective
Description: Charge corona wire cleaner error 2 Charge corona motor is disconnected. (The current at the charge corona motor is detected less than 83 mA.)
Causes: • Charge corona wire cleaner motor connector is defective or disconnected.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.