Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh D133 MP9002 — Trang 11/33

Code: 552-01

Description: Fusing reload temperature error 1: End thermistor The end thermistor (contact type) could not detect: • 100°C 25 seconds after the start of the warm-up cycle. • A change in temperature more than 16 degrees for 5 seconds. • The reload temperature with 56 seconds after the start of the fusing temperature control cycle.
Causes: • Fusing lamp disconnected • Thermistor connector loose, broken, defective • Thermistor out of position, installed incorrectly • Thermostat open

Code: 552-02

Description: Fusing reload temperature error 2: End thermistor The hot roller did not reach 100C within the prescribed time.
Causes: • Fusing lamp disconnected • Thermistor connector loose, broken, defective • Thermistor out of position, installed incorrectly • Thermostat open

Code: 552-03

Description: Fusing reload temperature error 3: End thermistor The hot roller did not reach the prescribed temperature within 3 sec, after the start of the fusing temperature control cycle.
Causes: • Fusing lamp disconnected • Thermistor connector loose, broken, defective • Thermistor out of position, installed incorrectly • Thermostat open

Code: 553

Description: Fusing thermistor error 4: End thermistor (software) The end thermistor (contact type) was at 240°C (464°F) for more than 1 second. The temperature is read 10 times every second. (at 0.1 s intervals).
Causes: • PSU defective • IOB control board defective • BICU control board defective

Code: 555

Description: Fusing lamp error After the start of the warmup cycle, a fusing lamp was at full power for 1.8 s but the hot roller did not turn.
Causes: • Thermistor bent, out of position • Fusing lamp disconnected • Circuit breaker opened

Code: 557

Description: Zero cross signal error High frequency noise was detected on the powe r line.
Causes: • No action required. The SC code is logged and the operation of the machine is not affected.

Code: 559

Description: Fusing jam: 3 counts At the fusing exit sensor the paper was detected late for three pulse counts (lag error), and SP1159 was on.
Causes: • If this SC occurs, the machine cannot be used until the service technician cancels the SC code. • This SC occurs only if SP1159 has been set to "1" (On). (Default: 0 (Off)).

Code: 569

Description: Fusing pressure release motor error During copying, the HP sensor could not detect the actuator, tried again 3 times and could not detect.
Causes: • Motor lock because of too much load • Motor driver defective • HP sensor defective, disconnected, connector defective, harness damaged