Description: ID Sensor Pattern Density High Error (Y). K: The density of the Black reading in the ID sensor patterns created between pages (SP3-300-001) is greater than the threshold value set by SP3-301-021. CMY: The density of the Cyan/Magenta/Yellow reading in the ID sensor patterns created between pages (SP3-300-002 to o004) is greater than the threshold value set by SP3-301-022.
Description: ID Sensor Pattern Density Low Error (K). K: The density of the Black reading in the ID sensor patterns created between pages (SP3-300-001) was less than the threshold value set by SP3-301-023 three times consecutively. CMY: The density of the Cyan reading in the ID sensor patterns created between pages (SP3-300-002 to 004) is less than the threshold value set by SP3301-24 three times consecutively.
Causes: • Abnormal development bias (Continuity fault) • Image transfer error
Remedy: • Check development bias continuity. • Check the image transfer unit.
Description: ID Sensor Pattern Density Low Error (C). K: The density of the Black reading in the ID sensor patterns created between pages (SP3-300-001) was less than the threshold value set by SP3-301-023 three times consecutively. CMY: The density of the Cyan reading in the ID sensor patterns created between pages (SP3-300-002 to 004) is less than the threshold value set by SP3301-24 three times consecutively.
Causes: • Abnormal development bias (Continuity fault) • Image transfer error
Remedy: • Check development bias continuity. • Check the image transfer unit.
Description: ID Sensor Pattern Density Low Error (M). K: The density of the Black reading in the ID sensor patterns created between pages (SP3-300-001) was less than the threshold value set by SP3-301-023 three times consecutively. CMY: The density of the Cyan reading in the ID sensor patterns created between pages (SP3-300-002 to 004) is less than the threshold value set by SP3301-24 three times consecutively.
Causes: • Abnormal development bias (Continuity fault) • Image transfer error
Remedy: • Check development bias continuity. • Check the image transfer unit.
Description: ID Sensor Pattern Density Low Error (Y). K: The density of the Black reading in the ID sensor patterns created between pages (SP3-300-001) was less than the threshold value set by SP3-301-023 three times consecutively. CMY: The density of the Cyan reading in the ID sensor patterns created between pages (SP3-300-002 to 004) is less than the threshold value set by SP3301-24 three times consecutively.
Causes: • Abnormal development bias (Continuity fault) • Image transfer error
Remedy: • Check development bias continuity. • Check the image transfer unit.
Description: Potential sensor output high error (K). Vd(700) greater than 800[-V] Details: In Vd detection, which is done at the beginning of process control, the measured potential (Vd) is converted to the potential when -700 V is applied to the drum (Vd700) and used to check the potential sensor.
Causes: Potential sensor dirty (foreign object, such as toner, entering the probe window) / potential sensor probe connector disconnected
Remedy: • Check if the potential sensor probe is clean. If it is dirty, blow it with air and then check again. If this does not work, replace the potential sensor. • Potential sensor probe connector is disconnected.
Description: Potential sensor output high error (C). Vd(700) greater than 800[-V] Details: In Vd detection, which is done at the beginning of process control, the measured potential (Vd) is converted to the potential when -700 V is applied to the drum (Vd700) and used to check the potential sensor.
Causes: Potential sensor dirty (foreign object, such as toner, entering the probe window) / potential sensor probe connector disconnected
Remedy: • Check if the potential sensor probe is clean. If it is dirty, blow it with air and then check again. If this does not work, replace the potential sensor. • Potential sensor probe connector is disconnected.
Description: Potential sensor output high error (M). Vd(700) greater than 800[-V] Details: In Vd detection, which is done at the beginning of process control, the measured potential (Vd) is converted to the potential when -700 V is applied to the drum (Vd700) and used to check the potential sensor.
Causes: Potential sensor dirty (foreign object, such as toner, entering the probe window) / potential sensor probe connector disconnected
Remedy: • Check if the potential sensor probe is clean. If it is dirty, blow it with air and then check again. If this does not work, replace the potential sensor. • Potential sensor probe connector is disconnected.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.