Description: Development Gamma High Error (Y). Development gamma > 3.0 Details: This SC is issued when the development gamma measured during process control was greater than 3.0
Causes: • Toner density too high • Condensation
Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.
Description: Development Gamma Low Error (K). Development gamma > 3.0 Details: This SC is issued when the development gamma measured during process control was smaller than 3.0
Causes: • Toner density error • The dustproof glass is dirty. • Transfer power pack defective
Remedy: • Check the toner supply system. • Clean the dustproof glass. • Replace the transfer power pack.
Description: Development Gamma Low Error (C). Development gamma > 3.0 Details: This SC is issued when the development gamma measured during process control was smaller than 3.0
Causes: • Toner density error • The dustproof glass is dirty. • Transfer power pack defective
Remedy: • Check the toner supply system. • Clean the dustproof glass. • Replace the transfer power pack.
Description: Development Gamma Low Error (M). Development gamma > 3.0 Details: This SC is issued when the development gamma measured during process control was smaller than 3.0
Causes: • Toner density error • The dustproof glass is dirty. • Transfer power pack defective
Remedy: • Check the toner supply system. • Clean the dustproof glass. • Replace the transfer power pack.
Description: Development Gamma Low Error (Y). Development gamma > 3.0 Details: This SC is issued when the development gamma measured during process control was smaller than 3.0
Causes: • Toner density error • The dustproof glass is dirty. • Transfer power pack defective
Remedy: • Check the toner supply system. • Clean the dustproof glass. • Replace the transfer power pack.
Description: Development gamma calculation error: Insufficient data (K). The number of valid data that can be used for development gamma calculation is smaller than 2.
Causes: • Toner density error • Condensation
Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.
Description: Development gamma calculation error: Insufficient data (C). The number of valid data that can be used for development gamma calculation is smaller than 2.
Causes: • Toner density error • Condensation
Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.
Description: Development gamma calculation error: Insufficient data (M). The number of valid data that can be used for development gamma calculation is smaller than 2.
Causes: • Toner density error • Condensation
Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.