Mã lỗi Ricoh D136 MPC8002SP CH-C1 — Trang 35/63

Code: SC560-00

Description: Web unit contact error Contact/separation control failed 3 times consecutively. Monitored when contact/separation mechanism is operating.
Causes: • Web unit contact motor/sensor defective • Feeler deformed or damaged • Contact/separation mechanism defective
Remedy: • Replace the motor. • Replace the sensor. • Replace the feeler. • Replace the unit.

Code: SC561-00

Description: Sensor 2: Heating Roller Front Disconnection 0 degrees or lower was detected for (t1) seconds consecutively. Number of times: 10 or more D135 (Japan): 50 (seconds) D136 (Japan)/D135 (NA): 50 (seconds) D136 (NA)/D135 (EU)/D136(EU): 50 (seconds) D137 (Japan): 50 (seconds) D138 (Japan)/D137 (NA)/D138 (NA)/D137 (EU)/D138 (EU): 50 (seconds) Monitored at: All times, though SC is not issued when temperature is not controlled (when in off mode/sleep mode, when a door, excluding the toner supply door, is open, or when the heater relay is off).
Causes: • Thermistor disconnection • Connecter contact failure
Remedy: • Replace the thermistor. • Reconnect the connector. • Replace the connector. • Replace the connector.

Code: SC562-02

Description: Sensor 2: Heating Roller Front: Reload Failure: Timeout 1 Failed to reach (T2) degrees centigrade after (t4) seconds from the start of heater control. D135 (Japan):T2 = 45, t4 = 80 D136 (Japan)/D135 (NA): T2 = 45, t4 = 80 D136 (NA)/D135 (EU)/D136(EU): T2 = 45, t4 = 80 D137 (Japan): T2 = 45, t4 = 80 D138 (Japan)/D137 (NA)/D138 (NA)/D137 (EU)/D138 (EU): T2 = 45, t4 = 80 Monitored at: Startup (Power-on, when a cover is closed, when fuser heater is under control)
Causes: • Thermopile lens smudged • Thermistor deformed or floating • Input voltage out of specification
Remedy: • Replace the thermopile. • Use with supported input voltage • Replace the IH coil/IH inverter. • Replace the unit.

Code: SC562-03

Description: Sensor 2: Heating Roller Front: Reload Failure: Timeout 2 Failed to reach reload temperature after (t5) seconds from the start of heater control. D135 (Japan):t5 = 350 D136 (Japan)/D135 (NA): t5 = 350 D136 (NA)/D135 (EU)/D136(EU): t5 = 350 D137 (Japan): t5 = 350 D138 (Japan)/D137 (NA)/D138 (NA)/D137 (EU)/D138 (EU): t5 = 350 Monitored at: Startup (Power-on, when a cover is closed, when fuser heater is under control)
Causes: • IH malfunctioning • Overheating prevention device worked.
Remedy: • Replace the thermopile. • Use with supported input voltage • Replace the IH coil/IH inverter. • Replace the unit.

Code: SC563-00

Description: Sensor 2: Heating Roller Front: Overheat detection (software) (T3) degrees centigrade or higher was detected for (t6) seconds consecutively. Number of times: 10 or more D135 (Japan):T3 = 250, t5 = 1 D136 (Japan)/D135 (NA): T3 = 250, t5 = 1 D136 (NA)/D135 (EU)/D136(EU): T3 = 250, t5 = 1 D137 (Japan): T3 = 250, t5 = 1 D138 (Japan)/D137 (NA)/D138 (NA)/D137 (EU)/D138 (EU): T3 = 250, t5 = 1 Monitored at: All times, though SC is not issued when temperature is not controlled (when in off mode/sleep mode, when a door, excluding the toner supply door, is open, or when the heater relay is off).
Causes: • Triac shorted. • IOB board defective.
Remedy: • Replace the IOB board. • Replace the unit.

Code: SC564-00

Description: Heating Roller Front: Overheat detection (hardware) Hardware detection of overheat condition. The heating roller front thermistor was detected as the cause.
Causes: • IOB defective • Fuser control software running out of control • Heating roller front thermistor defective • IH inverter supplied continuously (software error or temperature sensor malfunctioning
Remedy: • After removing the cause of the SC, Set "Fusing SC Clear" in the SP mode. • If necessary, replace: IOB/heating roller front thermistor/IH coil/IH inverter.

Code: SC569-02

Description: Pressure Release Error: HP failed 3 times Pressure release/Home position/control failed 3 times consecutively. Monitored when the pressure release mechanism is operating. Pressure Change: SP1-151-001 1:On/0: Off When this SP is set to OFF, SC detection is disabled.
Causes: • Pressure release motor, sensor defective • Feeler deformed or damaged • Pressure release mechanism defective
Remedy: • Replace the motor. • Replace the sensor. • Replace the feeler. • Replace the unit.

Code: SC569-03

Description: Pressure Release Error: Overrun When sensor A shows Low and Sensor B shows High. Except when home position is detected. Monitored when the pressure release mechanism is operating. Pressure Change: SP1-151-001 1:On/0: Off When this SP is set to OFF, SC detection is disabled.
Causes: • Pressure release motor, sensor defective • Feeler deformed or damaged • Pressure release mechanism defective
Remedy: • Replace the motor. • Replace the sensor. • Replace the feeler. • Replace the unit.