Description: Jogger Motor Error (D707) • When moving to the home position, home position was not detected within specified time (t0 ms). (The first time: jam display, the second time: SC) • When moving from the home position, home position was still detected after specified number of pulses (p1 pulses). (The first time: jam display, the second time: SC)
Causes: • Motor defective • Connecter disconnected • Overload • Home position sensor defective
Remedy: • Check the connections of the motor and home position sensor. • Replace the motor/home position sensor. • Replace the PCB.
Description: Positioning Roller Motor Error (D707) • When moving to the home position, home position was not detected within specified number of pulses (p0 pulses). (The first time: jam display, the second time: SC) • When moving from the home position, home position was still detected after specified number of pulses (p1 pulses). (The first time: jam display, the second time: SC)
Causes: • Motor defective • Connecter disconnected • Overload • Home position sensor defective
Remedy: • Check the connections of the motor and home position sensor. • Replace the motor/home position sensor. • Replace the PCB.
Description: Stack Plate-Center Motor Error (D707) • The drive unit in the staple tray does not return to the home position within a specified time (t0ms). (The first time: jam display, the second time: SC) • When the drive unit in the staple tray was moving away from the home position, the home position was still detected after a specified time (t1ms). (The first time: jam display, the second time: SC)
Causes: • Motor defective • Connecter disconnected • Overload • Home position sensor defective
Remedy: • Check the connections of the motor and home position sensor. • Replace the motor/home position sensor. • Replace the PCB.
Description: Stapler Plate-Front Motor Error (D707) • The drive unit in the staple tray does not return to the home position within a specified time (t0ms). (The first time: jam display, the second time: SC) • When the drive unit in the staple tray was moving away from the home position, the home position was still detected after a specified time (t1ms). (The first time: jam display, the second time: SC)
Causes: • Motor defective • Connecter disconnected • Overload • Home position sensor defective
Remedy: • Check the connections of the motor and home position sensor. • Replace the motor/home position sensor. • Replace the PCB.
Description: Stapler Plate-Rear Motor Error (D707) • The drive unit in the staple tray does not return to the home position within a specified time (t0ms). (The first time: jam display, the second time: SC) • When the drive unit in the staple tray was moving away from the home position, the home position was still detected after a specified time (t1ms). (The first time: jam display, the second time: SC)
Causes: • Motor defective • Connecter disconnected • Overload • Home position sensor defective
Remedy: • Check the connections of the motor and home position sensor. • Replace the motor/home position sensor. • Replace the PCB.
Description: Stapler Movement Motor Error (D707) • When moving to the home position, home position was not detected within specified time (t0 ms). (The first time: jam display, the second time: SC) • When moving from the home position, home position was still detected after specified time (t1 ms). (The first time: jam display, the second time: SC)
Causes: • Motor defective • Connecter disconnected • Overload • Home position sensor defective
Remedy: • Check the connections of the motor and home position sensor. • Replace the motor/home position sensor. • Replace the PCB.
Description: Stapler Rotation Motor Error (D707) • When moving to the home position, home position was not detected within specified time (t0 ms). (The first time: jam display, the second time: SC) • When moving from the home position, home position was still detected after specified time (t1 ms). (The first time: jam display, the second time: SC)
Causes: • Motor defective • Connecter disconnected • Overload • Home position sensor defective
Remedy: • Check the connections of the motor and home position sensor. • Replace the motor/home position sensor. • Replace the PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.