Description: Fusing thermistor open (end) The temperature of the hot roller remained below 0°C for 5 sec. at the end of the hot roller.
Causes: • Fusing thermistor out of its position because of incorrect installation • Fusing thermistor disconnected or defective • Power supply not within rated range (15% or more below rating)
Remedy: • Check the fusing thermistor is set correctly. • Replace the fusing thermistor. • Check the power supply source.
Description: Fusing end thermopile does not reload Temperature gradient detection:Temperature rise of 2 seconds is detected by five consecutive four degrees or less
Causes: • Fusing thermistor defective or out of position • Fusing thermistor modification/float • Outside input voltage guarantee
Remedy: • Check the fusing thermistor is set correctly. • Replace the fusing thermistor. • Check that the input voltage is within acceptable limits • Replace the fusing unit • Repace the BCU
Description: Fusing end thermopile does not reload • Time out (Non-rotating roller): Reload temperature not reached in 28 seconds after the fusing lamp control start • Time out (Rotating roller): Reload temperature not reached in 46 seconds after the fusing lamp control start
Causes: • Disconnection of the fusing lamp • After excessive temperature rise prevention unit operation
Remedy: • Check the fusing thermistor is set correctly. • Replace the fusing thermistor. • Check that the input voltage is within acceptable limits • Replace the fusing unit • Repace the BCU
Description: Fusing overheat error 2 (end) A fusing temperature over 250°C is detected at the center of the hot roller by the fusing temperature monitor circuit in the BCU board. The power was interrupted for more than 0.3 sec.
Causes: • TRIAC short on PSU (PSU defective) • BCU defective • Fusing thermistor defective • Power supply voltage unstable
Remedy: • Replace the PSU. • Replace the BCU. • Replace the fusing unit.
Description: Fusing overheat error 3 (end) After warmup, the center of the hot roller attained full operating temperature and maintained this temperature for 29 sec. without the hot roller rotating.
Causes: • Center hot roller thermistor installed incorrectly, disconnected. • Center hot roller thermistor defective
Remedy: • Check the hot roller thermistor is set correctly. • Replace the hot roller thermistor. • Replace the BCU. • Check that the input voltage is within acceptable limits. • Replace the fusing unit. • Replace the fusing lamp in the case of disconnection.
Description: Fusing Jam Detected for 3 Times Consecutively Consecutive fusing unit paper jams
Causes: Three consecutive paper jams occurred in the fusing unit. The paper jam counter for the fusing unit reaches 3 times. The paper jam counter clears after the paper feeds correctly. Note: This SC is issued only if SP1159 is set to "1".
Remedy: • Clean the fusing entrance/exit guides • Replace the fusing unit. • Replace the hot roller strippers
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.