Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh D249 MP2554 Cor-C1 — Trang 37/40

Code: SC875-02

Description: Delete all error (HDD erasure) (Data deletion failure). An error was detected before HDD/data erasure starts. (Failed to erase data/failed to logically format HDD)
Causes: • HDD logical formatting failed. • The modules failed to erase data.
Remedy: Turn the main power off/on.

Code: SC876-00

Description: Log Data Error An error was detected in the handling of the log data at power on or during machine operation.
Causes: • Damaged log data file. • Log encryption is enabled but encryption module is not installed. • Inconsistency of encryption key between NV-RAM and HDD. • Software bug.
Remedy: Try the SC876-01 to -99 solutions listed below. If it is not solved, do the following steps (for when only an HDD is replaced): 1. Disconnect the HDD and turn on the main power. 2. Execute SP5-801-019. 3. Turn off the main power. 4. Connect the HDD and turn on the main power. 5. Execute SP5-832-004. 6. Turn off the main power. * The following step is to configure the logging/encryption setting again. 7. Turn of the main power. 8. Set SP9-730-002 through -004 to 1. 9. Turn off/on the main power.

Code: SC876-01

Description: Log Data Error 1 An error was detected in the handling of the log data at power on or during machine operation.
Causes: Damaged log data file
Remedy: Initialize the HDD (SP5-832-004).

Code: SC876-02

Description: Log Data Error 2 An error was detected in the handling of the log data at power on or during machine operation.
Causes: Log encryption is enabled but encryption module is not installed.
Remedy: • Replace or set again the encryption module. • Disable the log encryption setting.

Code: SC876-03

Description: Log Data Error 3 An error was detected in the handling of the log data at power on or during machine operation.
Causes: Inconsistency of encryption key between NV-RAM and HDD.
Remedy: • Disable the log encryption setting. • Initialize LCS memory (SP5801-019). • Initialize the HDD (SP5-832-004).

Code: SC876-04

Description: Log Data Error 4 An error was detected in the handling of the log data at power on or during machine operation.
Causes: • Log encryption key is disabled but the log data file is encrypted. (NVRAM data corruption) • Log encryption key is enabled but the log data file is not encrypted. (NVRAM data corruption)
Remedy: Initialize the HDD (SP5-832-004).

Code: SC876-05

Description: Log Data Error 5 An error was detected in the handling of the log data at power on or during machine operation.
Causes: • Only the NV-RAM has been replaced with one previously used in another machine. • Only the HDD has been replaced with one previously used in another machine.
Remedy: • Attach the original NV-RAM. • Attach the original HDD. • With the configuration that caused the SC, initialize the HDD (SP5-832-004).

Code: SC876-99

Description: Log Data Error 99 An error was detected in the handling of the log data at power on or during machine operation.
Causes: Other causes
Remedy: