Description: Paper table motor lock – LCIT The paper table upper limit sensor or lower limit sensor does not change the status for more than 15 seconds after the paper table motor on signal is generated.
Causes: • Defective sensor • Defective motor • Mechanism blocked by foreign material
Description: Paper table motor lock – LCOT The paper table upper limit sensor or lower limit sensor does not change the status for more than 15 seconds after the paper table motor on signal is generated.
Causes: • Defective sensor • Defective motor • Mechanism blocked by foreign material
Description: Self-Diagnostic Error: ASIC The ASIC returned an error during the self-diagnostic test because the ASIC and CPU timer interrupts were compared and determined to be out of range.
Causes: • ACU board defective