Description: Paper table motor lock – LCIT The paper table upper limit sensor or lower limit sensor does not change the status for more than 15 seconds after the paper table motor on signal is generated.
Causes: • Defective sensor • Defective motor • Mechanism blocked by foreign material
Code: SC725
Description: Paper table motor lock – LCOT The paper table upper limit sensor or lower limit sensor does not change the status for more than 15 seconds after the paper table motor on signal is generated.
Causes: • Defective sensor • Defective motor • Mechanism blocked by foreign material
Code: SC780
Description: DF Gate signal error DF gate signal level does not change to ”H” 10 seconds after paper feed starts at the registration position.
Causes: • Harness error • ADF Board error
Code: SC781
Description: DF Connection error When an ADF for another model is connected.
Causes: • The wrong ADF is connected • Harness error • ADF Board error
Code: SC818
Description: Watch-dog error While the system program is running, other processes do not operate at all.
Causes: • Defective ACU board • Software error (ACU)
Code: SC819
Description: Kernel panic error Processing cannot be continued by kernel
Causes: • Software error (ACU)
Code: SC820
Description: Self-Diagnostic Error: CPU The central processing unit returned an error during the self-diagnostic test.
Causes: • Defective ACU board • Software error (ACU)
Code: SC821
Description: Self-Diagnostic Error: ASIC The ASIC returned an error during the self-diagnostic test because the ASIC and CPU timer interrupts were compared and determined to be out of range.