Các lỗi thường gặp

Code :
  • Code: SC720
  • Description: Paper table motor lock – LCIT The paper table upper limit sensor or lower limit sensor does not change the status for more than 15 seconds after the paper table motor on signal is generated.
  • Causes: • Defective sensor • Defective motor • Mechanism blocked by foreign material
  • Code: SC725
  • Description: Paper table motor lock – LCOT The paper table upper limit sensor or lower limit sensor does not change the status for more than 15 seconds after the paper table motor on signal is generated.
  • Causes: • Defective sensor • Defective motor • Mechanism blocked by foreign material
  • Code: SC780
  • Description: DF Gate signal error DF gate signal level does not change to ”H” 10 seconds after paper feed starts at the registration position.
  • Causes: • Harness error • ADF Board error
  • Code: SC781
  • Description: DF Connection error When an ADF for another model is connected.
  • Causes: • The wrong ADF is connected • Harness error • ADF Board error
  • Code: SC818
  • Description: Watch-dog error While the system program is running, other processes do not operate at all.
  • Causes: • Defective ACU board • Software error (ACU)
  • Code: SC819
  • Description: Kernel panic error Processing cannot be continued by kernel
  • Causes: • Software error (ACU)
  • Code: SC820
  • Description: Self-Diagnostic Error: CPU The central processing unit returned an error during the self-diagnostic test.
  • Causes: • Defective ACU board • Software error (ACU)
  • Code: SC821
  • Description: Self-Diagnostic Error: ASIC The ASIC returned an error during the self-diagnostic test because the ASIC and CPU timer interrupts were compared and determined to be out of range.
  • Causes: • ACU board defective