Description: [1401] Self-diagnosis error: Standard NVRAM The controller cannot recognize the standard NVRAM installed or detects that the NVRAM is defective.
Remedy: 1. Turn the main switch off and on. 2. Check the standard NVRAM is firmly inserted into the socket. 3. Replace the NVRAM. 4. Replace the controller.
Code: SC827
Description: Self-diagnostic error: Standard SRAM DIMM [XXXX]: Detailed error code [0201] Verification error Error detected during a write/verify check for the standard RAM (SRAM DIMM).
Remedy: 1. Turn the main switch off and on. 2. Replace the SRAM DIMM. 3. Replace the controller.
Code: SC828
Description: Self-diagnostic error : ROM [XXXX]: Detailed error code [0101] Check sum error 1 The boot monitor and OS program stored in the ROM DIMM is checked. If the check sum of the program is incorrect, this SC code is displayed. [0104] Check sum error 2 All areas of the ROM DIMM are checked. If the check sum of all programs stored in the ROM DIMM is incorrect, this SC code is displayed. [0105] ROM error The ROM DIMM is not of the recognized type.
Causes: • Defective ROM DIMM • Defective controller
Remedy: 1. Turn the main switch on and off. 2. Replace the ROM DIMM 3. Replace the controller.
Code: SC829
Description: Self-diagnosis error: optional RAM [XXXX]: Detailed error code [0302] Composition error (Slot 0) The result of checking the composition data of the RAM in Slot 0 (CN5) on the controller is incorrect. [0401] Verification error (Slot 1) The data stored in the RAM in Slot 1 does not match the data when reading. [0402] Composition error (Slot 1) The result of checking the composition data of the RAM in Slot 1 (CN6) on the controller is incorrect.
Remedy: 1. Turn the main switch off and on. 2. Check the connection between the BCU and controller. 3. Replace the controller. 4. Replace the BCU.
Code: SC835
Description: Self-diagnosis error: Centronics interface [XXXX]: Detailed error code [1102] Verification error The controller detects that the loop-back connector is not properly connected. [110C] DMA verification error A DMA data abnormality is detected even when the loopback connector is properly set. [1120] Loop-back connector error The loop-back connector is not set when starting the detailed self-diagnostics.
Remedy: 1. Turn the main switch off and on. 2. Check the connection between the Centronics connector and loop-back connector. 3. Reconnect the loop-back connector. 4. Replace the controller.
Code: SC836
Description: [1601] Self-diagnosis error: Font ROM (standard) The data in the font ROM (standard ROM-DIMM) is damaged. .
Causes: • Defective standard ROM-DIMM
Remedy: 1. Turn the main switch off and on. 2. Replace the standard ROM-DIMM.
Code: SC837
Description: [1602] Self-diagnosis error: Font ROM (option) The data in the font ROM (optional ROM-DIMM) is damaged.
Causes: • Defective optional ROM-DIMM
Remedy: 1. Turn the main switch off and on. 2. Replace the optional ROM-DIMM.