Description: FGATE: Off error [Y] The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for [K] ends. The PFGATE ON signal still asserts when the next job starts.
Causes: Defective connection between the controller board and EGB. Defective cable between the EGB and LDB.
Remedy: 1. Check the connectors. 2. Replace the LDB. 3. Replace the EGB.
Code: 234
Description: FGATE: On error [M] The PFGATE register of GAVD does not assert within 5 seconds after processing the image in normal job or MUSIC for [M] started.
Causes: Defective connection between the controller board and EGB. Defective cable between the EGB and LDB.
Remedy: 1. Check the connectors. 2. Replace the LDB. 3. Replace the EGB.
Code: 235
Description: FGATE: Off error [M] The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for [M] ends. The PFGATE ON signal still asserts when the next job starts.
Causes: Defective connection between the controller board and EGB. Defective cable between the EGB and LDB.
Remedy: 1. Check the connectors. 2. Replace the LDB. 3. Replace the EGB.
Code: 236
Description: FGATE: On error [C] The PFGATE register of GAVD does not assert within 5 seconds after processing the image in normal job or MUSIC for [C] started.
Causes: Defective connection between the controller board and EGB. Defective cable between the EGB and LDB.
Remedy: 1. Check the connectors. 2. Replace the LDB. 3. Replace the EGB.
Code: 237
Description: FGATE: Off error [C] The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for [C] ends. • The PFGATE ON signal still asserts when the next job starts.
Causes: Defective connection between the controller board and EGB. Defective cable between the EGB and LDB.
Remedy: 1. Check the connectors. 2. Replace the LDB. 3. Replace the EGB.
Code: 240
Description: LDB error [K] The EGB detects LDB error an the few times consecutively when LDB unit turns on after LDB initialization.
Causes: Defective LDB
Remedy: 1. Replace the LDB.
Code: 241
Description: LDB error [Y] The EGB detects LDB error a few times consecutively when LDB unit turns on after LDB initialization
Causes: Defective LDB
Remedy: 1. Replace the LDB.
Code: 242
Description: LDB error [M] The EGB detects LDB error a few times consecutively when LDB unit turns on after LDB initialization