Description: LDB error [C] The EGB detects LDB error a few times consecutively when LDB unit turns on after LDB initialization.
Causes: Defective LDB
Remedy: 1. Replace the LDB.
Code: 270
Description: LDU shutter error Sensor output does not change even if 1 second passes after the LDU shutter motor is on.
Causes: Sensor defective or LDU shutter motor defective
Remedy: 1. Replace the LDU shutter sensor or shutter motor.
Code: 300
Description: High voltage power board: Charge voltage output error [K] The measured voltage is not proper when EGB measures the charge output for each color.
Causes: Defective charge roller. Defective connectors. Disconnected harness. Defective high voltage power 1.
Remedy: 1. Check the connectors. 2. Replace the PCU for black. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.
Code: 301
Description: High voltage power board: Charge voltage output error [M] The measured voltage is not proper when EGB measures the charge output for each color.
Causes: Defective charge roller. Defective connectors. Disconnected harness. Defective high voltage power 1.
Remedy: 1. Check the connectors. 2. Replace the PCU for magenta. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.
Code: 302
Description: High voltage power board: Charge voltage output error [C] The measured voltage is not proper when EGB measures the charge output for each color.
Causes: Defective charge roller. Defective connectors. Disconnected harness. Defective high voltage power 1.
Remedy: 1. Check the connectors. 2. Replace the PCU for cyan. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.
Code: 303
Description: High voltage power board: Charge voltage output error [Y] The measured voltage is not proper when EGB measures the charge output for each color.
Causes: Defective charge roller Defective connectors Disconnected harness Defective high voltage power 1
Remedy: 1. Check the connectors. 2. Replace the PCU for yellow. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.
Code: 304
Description: Charge AC bias error [K] The charge current less than 200 mkA is detected.
Causes: Defective charge roller. Defective connectors. Disconnected harness. Defective high voltage power 1.
Remedy: 1. Check the connectors. 2. Replace the PCU for black. 3. Replace the drum positioning plate.
Code: 305
Description: Charge AC bias error [M] The charge current less than 200 mkA is detected.
Causes: Defective charge roller. Defective connectors. Disconnected harness. Defective high voltage power 1.
Remedy: 1. Check the connectors. 2. Replace the PCU for magenta. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.